Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25

Enlaces rápidos

POWERFUL SOLUTIONS. GLOBAL FORCE.
L2661
Rev. C
Index:
English:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Français:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-12
Deutsch: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-18
Italiano: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19-24
Español: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25-30
Nederlands: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31-36
1.0 IMPORTANT RECEIVING INSTRUCTIONS
Visually inspect all components for shipping damage. Shipping
damage is not covered by warranty. If shipping damage is found,
notify carrier at once. The carrier is responsible for all repair and
replacement costs resulting from damage in shipment.
SAFETY FIRST
2.0 SAFETY ISSUES
Read all instructions, warnings and cautions
carefully. Follow all safety precautions to avoid
personal injury or property damage during system
operation. Enerpac cannot be responsible for
read.eps
damage or injury resulting from unsafe product use, lack of
maintenance or incorrect product and/or system operation. Contact
Enerpac when in doubt as to the safety precautions and operations.
If you have never been trained on high-pressure hydraulic safety,
consult your distribution or service center for a free Enerpac
Hydraulic safety course.
Failure to comply with the following cautions and warnings could
cause equipment damage and personal injury.
A CAUTION is used to indicate correct operating or maintenance
procedures and practices to prevent damage to, or destruction of
equipment or other property.
A WARNING indicates a potential danger that requires correct
procedures or practices to avoid personal injury.
A DANGER is only used when your action or lack of action may
cause serious injury or even death.
WARNING: Wear proper personal protective gear
when operating hydraulic equipment.
WARNING: Stay clear of loads supported by
hydraulics. A cylinder, when used as a load lifting
device, should never be used as a load holding
device. After the load has been raised or lowered, it must
always be blocked mechanically.
WARNING: USE ONLY RIGID PIECES TO HOLD
LOADS. Carefully select steel or wood blocks that
®
are capable of supporting the load. Never use a
hydraulic cylinder as a shim or spacer in any lifting or
pressing application.
03/12
Instruction Sheet
PMUxxQ Portable Electric
Torque Wrench Pump
PMU-10022Q / PMU-10027Q (not pictured)
• For single-acting torque wrenches.
• Remote pendant operation.
• Heat exchanger prevents heat build-up.
• Glycerin-filled pressure gauge.
PMU-10422Q / PMU-10427Q
• For double-acting torque wrenches.
• Remote pendant operation.
• Heat exchanger prevents heat build-up.
• Time-out circuit stops motor after 10-15 seconds of idle.
• Glycerin-filled pressure gauge.
• Adjustable pressure relief valve.
DANGER: To avoid personal injury keep hands
and feet away from cylinder and workpiece
during operation.
WARNING: Do not exceed equipment ratings. Never
attempt to lift a load weighing more than
the capacity of the cylinder. Overloading causes
equipment failure and possible personal injury. The cylinders
are designed for a max. pressure of 700 bar [10,000 psi]. Do
not connect a jack or cylinder to a pump with a higher
pressure rating.
Never set the relief valve to a higher pressure than
the maximum rated pressure of the pump. Higher
settings may result in equipment damage and/or
personal injury.
WARNING: The system operating pressure must not
exceed the pressure rating of the lowest rated
component in the system. Install pressure gauges in
the system to monitor operating pressure. It is your window
to what is happening in the system.
Tabla de contenido
loading

Resumen de contenidos para Enerpac PMUQ Serie

  • Página 25: Importantes Instrucciones De Recepción

    Lea todas las instrucciones, advertencias y precauciones. Acate todas las precauciones de seguridad para evitar lesiones personales o daños a la propiedad durante la operación del sistema. ENERPAC no read.eps puede ser responsable de daños o lesiones que resulten de no usar el producto de forma segura, falta de mantenimiento o aplicación incorrecta del producto y/u operación del sistema.
  • Página 26: Especificaciones

    óptimo, no exponga el equipo a temperaturas de 65°C [150°F] o Servicio ENERPAC autorizado en su zona para prestarle mayores. Proteja las mangueras y cilindros de salpicaduras de servicio de reparaciones. Use únicamente aceite ENERPAC a soldadura.
  • Página 27: Instalación

    En caso necesario, añada el aceite con la inscripción “ENERPAC SERIE 800 - 800 BAR/11.600 hidráulico Enerpac para situar el nivel de aceite hasta unos PSI MÁX”. Apriete con la mano los anillos de seguridad 2,5 centímetros por debajo del orificio de llenado/ventilación.
  • Página 28: Eliminación Del Aire

    Cuando utilice el combinado de Utilice unos cables cortos de alimentación eléctrica para evitar llave dinamométrica y bomba Enerpac, las mangueras de la pérdidas de potencia. El motor de la bomba puede funcionar Serie 800 están diseñadas para que la salida de la bomba a un menor voltaje, pero la velocidad del motor y el flujo de correspondiente al avance sólo se pueda conectar a la entrada...
  • Página 29: Ajuste De La Presión (Par De Torsión)

    5.3 Ajuste de la presión (par de torsión) viejo. CUIDADO: Realice estos ajustes ANTES de colocar la Añada aceite hidráulico Enerpac nuevo, a través del orificio de llave dinamométrica en la cabeza de la tuerca o el llenado/ventilación hasta que el nivel de aceite se encuentre tornillo.
  • Página 30: Cuadro De Solución De Problemas

    Si un fusible se funde, analizar y orificio de llenado/ventilación con nuevo aceite hidráulico corregir la fuente de la falla. Luego, sustituir el fusible por Enerpac. La capacidad del depósito es de 0,75 galones (2,8 un fusible nuevo correspondiente. Para conocer los fusibles litros).

Este manual también es adecuado para:

Pmu-10022qPmu-10027qPmu-10422qPmu-10427qPmu q serie

Tabla de contenido