MasterCool 98310 Manual De Instrucciones página 4

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

and platform to turn the unit off. (If the scale was turned off, follow steps (1 through 4) of
BASIC CHARGING, then follow the REPEAT CHARGING steps.)
BASIC RECOVERY
1. Follow steps 1 through 6 in BASIC CHARGING.
2. Begin recovery.
LINE VACUUM AND RECOVERY WITH SOLENOID
1. Place tank on scale and connect line between tank and IN fitting then connect OUT fitting to
vacuum pump or recovery machine. Do NOT open tank valve.
2. Turn on platform and monitor.
3. Press CHARGE/PAUSE button.
4. Set charge weight to 1 lb. (0.45 Kg) using CLEAR, ⇑, ⇓, and SHIFT buttons.
5. When ready to vacuum/recover press ENTER and platform valve will open.
6. When done with vacuuming/recovery, press CLEAR to close valve.
7. Continue to PROGRAM CHARGING step 2, or, if done with line recovery, remove hose.
PROGRAM RECOVERY WITH SOLENOID
Push-Pull
1. Connect line from DOT tank vapor port to IN fitting on platform.
2. Vacuum line between tank and valve using LINE VACUUM and RECOVERY WITH SOLENOID.
3. Connect line from OUT fitting on platform to IN fitting on recovery machine.
4. Connect line from system liquid port to tank liquid port.
5. Press TARE/ENTER then CHARGE/PAUSE.
6. Set recovery weight using CLEAR, ⇑, ⇓, and SHIFT buttons. (If recovery weight is not known,
enter an amount larger than best estimate.)
7. When ready to recover press ENTER to open platform valve.
8. Valve will close and alarm sound when recovery weight is reached. If recovery is done, but
recovery weight has not been reached, press CLEAR to close valve. If tank full weight is
reached, FULL will be displayed and valve will close. (see INSTRUCTIONS FOR SETTING TANK
CAPACITY)
Vapor/Liquid
1. Connect line from OUT fitting on platform to tank.
2. Vacuum line between tank and valve using LINE VACUUM AND RECOVERY WITH SOLENOID.
3. Connect line from recovery machine to IN fitting on platform.
4. Follow steps 5 to 8 in Push/Pull.
INSTRUCTIONS FOR SETTING TANK CAPACITY
1. Turn on the unit.
2. Select desired units using UNITS/SHIFT.
3. Press and hold down the UNITS/SHIFT again until the last digit in display "blinks."
4. Use CLEAR, ⇑, ⇓ and shift buttons to input the empty tank weight.
5. Press ENTER to save the empty tank weight. The display will read "GOOD" to confirm.
4
www.mastercool.com
Tabla de contenido
loading

Este manual también es adecuado para:

98315

Tabla de contenido