Ingersoll Rand Expert Torque Analyzer Manual Del Usuario página 4

Ocultar thumbs Ver también para Expert Torque Analyzer:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
EN
Power
Weight
Data Output:
Serial Interface
Accuracy
Zero Drift
Overload Capacity
Storage Temperature Range
Operating Temperature Range
Temperature Stability
Sealing
Humidity
Frequency Response
Calibration
Warranty
Battery Charger Input
Battery Charger Output
EN-3
Table 5 - Specifications
Rechargeable NiMH battery or Powered directly from Battery Charger
1.0Kg (EXTA), 2.05Kg (EXTT)
.0Kg (EXTA), 2.05Kg (EXTT)
Serial RS232 Data.
9 way female 'D' connector.
±1% of rated maximum transducer capacity.
<0.1% of rated maximum transducer capacity.
110% of stated maximum transducer capacity.
0° to +50° Celsius.
+5° to +40° Celsius.
±0.1% per ° Celsius.
IP40
5% to 75% Non Condensing.
User selectable in 14 steps from 75Hz to 4608Hz.
Issued with calibration certificate traceable to national and international standards. 12 months typical
recalibration interval.
12 months parts and labor.
100-240V AC, 50-60 Hz.
15V DC, 1Amp.
45652906_ed1
Tabla de contenido
loading

Este manual también es adecuado para:

Expert torque tester

Tabla de contenido