Maintenance and cleaning

Fig. 35-36
Ordinary maintenance - Filters
Recommended maintenance intervals: because levels of air pollution depend typically on geographical location and are
variable, the life of the filters will be similarly variable. With this general consideration in mind, check following alarms for
filter maintenance:
• Pre-alarm: actives the notice about filters checking and cleaning (See:Operation and Use: Pre-alarm:"Checking filters")
• Alarm: actives the notice about clogged filters (See: Operation and Use: Alarm:"Filters replacing")
Resetting filters timer (See: Operation and Use: "User operation menu", "Resetting filters timer") is resetted also the
counter.
NOTE Failure to clean or replace filters can seriously affect system efficiency, causing:
- increased pressure losses in the air circulation system and reduced airflow;
- drop in system performance and comfort levels caused by pressure losses.
In case of filters cleaning or filters replacing
Fig. 35 - Filters removing
To join to filters case: managing the front panel, you need to remove filters closing caps before.
To remove filters closing caps: you have to swipe caps with your hand, following the direction shown on closing caps.
Now filters are available to be removed: extracting with your hand is sufficient to remove filters.
Fig. 36 - Filters mounting
Inserit filters with hands, into referred cases (sited on the front panel).
To replace filters correctly, you have to fix filters closing caps on the front panel.
To fix filters closing caps: you need to swipe with your hand, following the opposite direction to what is shown on closing
caps.
Extra-ordinary maintenance - Removing the front panel
Before any activity, please verify that the product is disconnetted to the power supply.
Removing front panel and Mounting front panel, are considered Extra-ordinary maintenance and must be carried out by
professionally qualified personnel.
Fig. 11-12
Removing the front panel
Managing the front panel, remove screws manually using: Torx screw driver, type T25.
IMPORTANT: Don't use drill, but remove screws only manually.
Fig. 15-16
Mounting the front panel
Managing the front panel, apply screws manually, using: Torx screw driver, type T25, torque 1,0 N/m.
IMPORTANT: Don't use drill, but apply screws only manually.
40