Dea NET24N Instrucciones De Uso página 34

Ocultar thumbs Ver también para NET24N:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 123
WARNING To ensure an appropriate level of electrical safety always keep the 230V
power supply cables apart (minimum 4mm in the open or 1 mm through insulation) from
low voltage cables (motors power supply, controls, electric locks, aerial and auxiliary
circuits power supply), and fasten the latter with appropriate clamps near the terminal
boards.
WARNING If the power cable is damaged, it must be replaced by the manufacturer or
its technical assistance service or, in any case, by a person with similar qualifications to
prevent any risk.
WARNING All installation, maintenance, cleaning or repair operations on any part of
the system must be performed exclusively by qualified personnel with the power supply
disconnected working in strict compliance with the electrical standards and regulations
in force in the nation of installation.
Cleaning and maintenance destined to be performed by the user must not be performed
by unsupervised children.
WARNING Using spare parts not indicated by DEA System and/or incorrect re-assem-
bly can create risk to people, animals and property and also damage the product. For this
reason, always use only the parts indicated by DEA System and scrupulously follow all
assembly instructions.
WARNING Changing the closing intensity could lead to dangerous situations. Therefore,
qualified personnel should only perform increases to the closing force. After adjustment,
compliance with regulatory limits values should be detected with a force impact-mea-
suring instrument. The sensitivity of the obstacle detection may be adjusted gradually
to the door (see programming instructions). The anti-crushing device operation must be
checked after each manual adjustment. Manual modification of the force can only be
done by qualified personnel by performing the measurement test according to EN 12445.
Modifications to the force adjustment must be documented in the machine manual.
WARNING The compliance of the internal sensing obstacles device to requirements
of EN12453 is guaranteed only if used in conjunction with motors fitted with encoders.
WARNING Any external security devices used for compliance with the limits of impact
forces must be conform to standard EN12978.
WARNING In compliance with EU Directive 2012/19/EU on waste electrical and elec-
tronic equipment (WEEE), this electrical product should not be treated as municipal
mixed waste. Please dispose of the product and bring it to the collection for an appropri-
ate local municipal recycling.
E
vEryThINg ThAT Is NOT ExprEssLy prOvIdEd fOr IN ThE INsTALLATION mANuAL Is NOT ALLOWEd
ErATOr OpErATION Is ONLy ENsuEd WhEN ThE rEpOrTEd dATA Is rEspEcTEd
fOr dAmAgE cAusEd by fAILurE TO cOmpLy WITh ThE INsTrucTIONs cONTAINEd IN ThIs mANuAL
fEcTINg ThE EssENTIAL fEATurEs Of ThE prOducT
dEEmEd ApprOprIATE ANd AT ANy TImE IN OrdEr TO TEchNIcALLy
ThE prOducT WIThOuT bEINg rEquIrEd TO updATE ThIs dOcumENT
32
. T
,
c
ThE
OmpANy rEsErvEs ThE rIghT TO mAKE ANy chANgEs
,
sTrucTurALLy ANd cOmmErcIALLy ImprOvE
.
. c
OrrEcT Op
hE cOmpANy dOEs NOT rEspONd
. W
IThOuT Af
-
-

Hide quick links:

Tabla de contenido
loading

Tabla de contenido