ENGLISH
Function
Capacitance
Maximum Input: 600V AC RMS or 600V DC
Temperature
Frequency
Duty Cycle
Sensitivity: 250mV and < 20V RMS
Maximum Input: 600V AC or 600V DC RMS
OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V DC or 600V AC RMS
• Diode Test: Approx. 1mA, open circuit voltage ~3.0V DC
• Continuity Check: Audible signal <10Ω, max current 1.5mA
• Sampling Frequency: 3 samples per second
• Auto Power off: After 10 minutes of inactivity.
• Overload: "OL" indicated on display
• Polarity: "-" on display indicates negative polarity
• Display: 3-3/4 digit, 4000 Count, 128 x 64 pixel OLED display
4
ELECTRICAL SPECIFICATIONS
Range
40.00nF
400.0nF
4.000μF
40.00μF
400.0μF
4.000mF
-40° to 104°F
>104° to 932°F
>932° to 1832°F
-40° to 40°C
>40° to 500°C
>500° to 1000°C
10Hz to
1MHz
0.1% to 99.9%
(≤100kHz)
Resolution
0.010nF
0.100nF
0.001μF
0.010μF
0.100μF
0.001mF
1°F
1°F
1°F
1°C
1°C
1°C
0.001Hz
to 1kHz
0.1%
(Range: 10% – 90%)
Accuracy
±(4% + 25 digits)
±(4% + 8 digits)
±(10% + 9 digits)
±(2.0% + 8 digits)
±(1.6% + 5 digits)
±(2.0% + 2 digits)
±(2.0% + 4 digits)
±(1.5% + 3 digits)
±(1.5% + 2 digits)
±(0.1% + 5 digits)
±1.5%