Troubleshooting Guide - Metabo HPT WH 18DDX Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

● To avoid injury from an accidental start, turn the switch OFF and remove the plug from the power source
or remove the battery from the main body before making any adjustments.
● All electrical or mechanical repairs should be done only by qualifi ed service technicians. Contact
metabo HPT Authorized Service Center.
Problem
Tool doesn't run
Tool suddenly stopped
Tool bits
-can't be attached
-fall off
Switch can't be pulled
An abnormal high-pitched
noise occurs when the
switch trigger is pulled.
Screw head slips or comes
loose.
Battery will not charged.
0000WH18DDX_metabo.indb 17
0000WH18DDX_metabo.indb 17

TROUBLESHOOTING GUIDE

WARNING
Possible Cause
No remaining battery power
The switch trigger was held down while
the battery was inserted.
Tool was overburdened
The battery is overheated.
The switch trigger was held down for
5 minutes or more.
The shape of the attachment portion
doesn't match
Forward/reverse selector button is
positioned halfway
The switch trigger is being pulled only
slightly.
Bit number doesn't match with the screw
size
The bit is worn
Battery not installed into charger properly. Insert battery into charger until charge
Charger not plugged in.
Battery temperature too hot
Battery temperature too cold
Possible Solution
Charge the battery.
The safety function was activated.
If the switch trigger is released once and
then pulled again, the tool will run.
Get rid of the problem causing the
overburden.
Let the battery cool down.
This is not a malfunction.
The motor was automatically stopped to
prevent failure of the tool.
Use a bit with a hexagonal shaft that has a
width across fl ats of 6.35 mm.
If you are using an L-type tool bit, replace it
with an S-type bit.
Press the button fi rmly into position for the
desired direction of rotation.
This is not a malfunction.
It does not occur if the switch trigger is
pulled more fully.
Install a suitable bit.
Replace with a new bit.
status lamp (red) appears.
Plug charger into a working receptacle.
Remove battery from charger, cool battery.
For more detail, refer to "Charging
Method".
Remove battery from charger, move
battery and charger to a surrounding air
temperature of above 32°F (0°C).
For more detail, refer to "Changing
Method".
English
17
2020/05/28 11:33:35
2020/05/28 11:33:35
Tabla de contenido
loading

Tabla de contenido