Anleitung LC4-25/SL 4-25
Mounting
The controller is mounted to the external wall.
If there are already empty conduits in the sauna wall
for installing the cables, fasten the controller with the
cable bushing over the empty conduit.
When installing the controller together with the SC10
T, you must break out the mutually opposed cable
bushings and use the supplied duct connector. The
duct connector has to be used in order to ensure
electrical safety. This results in a gap of 29 mm
between both devices (Fig. 2).
2
08.09.2003 17:38 Uhr
approx. 20 cm
Seite 9
The internal device (SL4-25) can be flush mounted to
a wall, the ceiling, a corner or edge of the sauna
room. The corresponding connection cable (for
control) is installed on the roof of the sauna room.
Fig. 3 (sample mounting)
3
The cable is guided through an 8 mm bore hole and
connected to terminals V, B, R, G and Y with the
stripped individual wires as shown in the connection
diagram.
GB
9