Discharge Pipe Assembly; Electrical Connection; Pre-Start Checks - Espa Jardino Triton G 90M A Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 5
2. HANDLING
The pumps are supplied suitably packaged to pre-
vent damage in transit. Before unpacking, check
that the packaging has not been damaged or de-
formed,
Lift and handle the product with care and with
the right tools.
3. INSTALLATION
These pumps are designed for indoor use.
3.1. Fixing
The pump can rest on the floor or be suspended
from a cable or the like.
The pump must never be supported by the
electric cable or the discharge line (fig.2).
If so wished the level of water for pump starting and
stopping can be set by sliding the float cable by its
hook.
Check that the level float can move freely (Fig.2).
The maximum depth of immersion is 7 m.

3.2. Discharge pipe assembly

The pumps are supplied ready to be connected a 1
1/4" line. However, if the geometric height is
considerable and the paths are long and winding,
we recommend using lines with a larger diameter,
to avoid head loss due to friction as much as
possible
and
to
obtain
performance possible.
Pipework must be supported and their weight must
not rest on the pump.
It is advisable to fit a check valve to prevent the
pipes remaining empty. This check valve must
allow solids of up to at least 10 mm to pass.
If a plastic hose is chosen instead of a metallic line,
make sure it can withstand the pressure provided
by the pump. Prevent the hose from becoming
twisted because, in addition to preventing the
desired flow, proper pump operation will be
hindered.

3.3. Electrical connection

The electrical installation must have a multi-
pole isolator with minimum 3 mm contact
openings, The protection of the system will
be
based
on
(Δfn = 30 mA).
The connection and its dimensioning must be per-
formed by a qualified installer according to the
needs of the facility and following the regulations in
force in each country.
The motor has built-in thermal protection
which disconnects the power supply in the
event of overload.
the
best
hydraulic
a
differential
switch

3.4. Pre-start checks

Ensure the voltage and frequency of the
supply corresponds to the values indicated
on the electrical data label.
Ensure that the pump is submerged as shown in
Fig.2.
THIS PUMP MUST NEVER BE DRY RUN.
4. STARTING
Ensure all valves in the pipework are open.
Connect the power supply switch. Water will never
flow at the end of the line immediately; if the path is
long, wait a few minutes.
Check that the absorbed current is the same as
marked on the name plate.
If the motor does not start or no water flows at the
end of the line, try to find the anomaly using the
troubleshooting guide in point 8.
5. MAINTENANCE
Under normal conditions these pumps require no
special or planned maintenance.
During frosty periods, remember to drain the
line.
Clean the pump by having it pump clean
water when it is to be withdrawn in order to
prevent deposition of sand or other materials.
If the pump is not to be operated for a long
period it is recommended to remove it from
the installation, drain down and store in a dry,
well ventilated place.
ATTENTION: In the event of faults or
damage occurring to the pump, repairs
should only be carried out by an authorised
service agent.
The
Official
Technical
www.jardinopool.eu.
When the pump is eventually disposed of, please
note that it contains no toxic or polluting material.
All main components are material identified to allow
selective disposal.
9
EN
Services
list
is
in
Tabla de contenido
loading

Este manual también es adecuado para:

Jardino triton i

Tabla de contenido