Behavior In Cases Of Error - Nussbaum SPRINTER MOBIL 2500 Instrucciones De Servicio

Ocultar thumbs Ver también para SPRINTER MOBIL 2500:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

To allow the system to lower further, it is neces-
sary to release the „LOWER" button (4) and press
it again.
A signal tone sounds until the system has reached
the lowest position.
• The entire lowering process must be observed.
• If the lift is in the detectable lowest position, re-
move the polymer overlays and drive the vehicle
from the lift
6

Behavior in cases of error

Defective operational readiness of the system may
be due to a simple error. Check the system for the
listed sources of error.
If the error cannot be removed after an inspection
to the named causes, then inform customer service
or your dealer.
Problem: Motor does not start
Possible causes:
No power supply
The main switch (2) is
not switched on, or is
defective
Defective fuse
"LIFT" (3) button defec-
tive
Motor defective
Problem: Motor starts, load is not lifted
Possible causes:
Load is too heavy
Hydraulic oil filling level
is too low
Emergency discharge
fixture is not closed
Pressure line leaking
The connector for the
left is designed for a
clockwise phase order.
OPI_SPRINTER MOBIL 2500-3000_V3.1_DE-EN-FR-ES-IT
Remedy:
Check the power supply
Check the main switch
(2).
Have fuses checked
Inform customer service
Inform customer service
Remedy:
Unload the lift
Refill hydraulic oil
Check emergency dis-
charge fixture
Inform customer service
Your power socket
may not match. One
of the phases must be
swapped.
61
Tabla de contenido
loading

Este manual también es adecuado para:

Sprinter mobil 3000Hymax pro 3000Hymax pro 2500

Tabla de contenido