Auto-Hold function
The last measurement value will continue to display for about
5 seconds after removing the device from the measured material.
During this period the LEDs will blink and show the last measure-
ment value. As soon as only the first green LED blinks, the device
is ready to make a new measurement.
Functional and operational safety is only warranted when the
instrument is operated within the specified climatic conditions
!
and is only used for those purposes for which it is designed.
The assessment of measurement results and actions taken as a
consequence lie in the user's scope of responsibility, depending
on the given type of work.

Technical data

Measurement principle
Material
Measurement range, wood group A
Measurement range, wood group B
Accuracy
Nominal temperature
Permissible operating temperature
Permissible storage temperature
Permissible max. relative humidity
Power supply
Battery service life
Technical revisions reserved. 01.15.
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collec-ted separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
www.laserliner.com/info
WoodTester Compact
Resistive material moisture
measurement by way of
integrated electrodes
2 wood scales
9% ... 23%
11% ... 27%
± 2%
22 °C
0 °C ... 40 °C
-10 °C ... 70 °C
85%
1 x 6LR61 9 V
approx. 40 hours
09