Capacitance measurement

To take a capacitance measurement,
turn the rotary switch to position „CAP"
and press the „Mode" button three
times to activate the „Capacitance
measurement" function. Then connect
the measuring contacts to the object
to be tested. In the case of poled
capacitors, connect the positive pole
to the red test prod.
10
Frequency and duty factor measurements
To take a frequency measurement, turn
the rotary switch to position „Hz". Then
connect the measuring contacts to the
object to be tested. Press the „Mode"
button to switch from Hz to % (duty
factor).
11
Auto range/Manual range
The „Auto range" function is activated automatically when the
meter is switched on. Auto range searches for the best possible
range for each measurement in the corresponding measuring
functions. Press the „Range" button to activate manual range
selection, then press the „RANGE" button several times until
you reach the desired range. Pay attention to changes in decimal
places or units. To return to the „Auto range" range, press the
„RANGE" button and hold it down for 2 seconds. „AUTO"
reappears on the display. The „Range" function can only be
used for voltage, current and resistance measurements.
MultiMeter-Compact
Black
Black
Red
+
+
Red
21
GB