Recommended system cables see
When using other cables for the system cable, note the different colour coding. The
outer diameter must not exceed 7.5 mm.
11.1 Strip the shielding (a) off from the system cables (approx. 40 mm).
11.2 Place the union nut (c) on the system cable (b) up to the stop.
☞
The cable cores are marked with numbers 1 through 4.
11.3 Latch the cable cores (d) into the cable core guides (e) according to their colours.
A: Union nut
B: FAR-Order-No. 2000104272
FAR-Order-No. 2000104274
FAR-Order-No. 2000100801
FAR-Order-No. 2000100852
11.4 Cut off the protruding ends of the cable core so that they are flush, i. e. so that they
do not protrude.
11.5 Place the union nut (c) on the electric T-junction (f) and tighten with the required
torque (1.2 Nm).
Caution!
Ensure correct polarity.
Each core cable colour must be in the same cable core guide on both union nuts.
☞
When the union nut is being tightened, an electric contact and the pull-relief are
automatically established.
Special seals provide protection against dust and water.
12. Assembly Instructions
Warning!
Use the fitting only with non-return valves and the grit filters specified.
Failure to observe can result in an increased bacterial load in drinking water and
cause a health risk or even risk of death.
☞
Important!
• Before installing, flush the pipes in compliance with DIN 1988.
• Do not shorten the connector hoses located at the fitting.
☞
Important!
Reflecting surfaces can influence the sensor. There is a risk of having permanent
reflections.
12.1 Install the fitting (a) on the washbasin (b).
☞
The corner valves (c) must be provided by the customer.
12.2 Screw the connecting hose (d) on to the corner valve.
12.3 Install the line connection between the fitting and the electric T-junction.
Chapter
10., Accessories.
A
1
brown
2
white
3
blue
4
black
B
red
white
blue
black
7