Disconnect the air supply during maintenance on the tool.
Regularly clean and dry the filter in the system and the pneumatic tool air inlet opening.
Lubricate any quick-disconnect coupling on the system to prevent jamming.
Drain condensation from air filter and from the compressor on a daily basis.
In order to avoid rust formation and to minimize wear, clean and lubricate the tool after each use.
Check the tool regularly on loose bolts/screws or parts.
In case of power loss: have the tool repaired.
Only trained and qualified engineers are allowed to adjust or repair the tool.
In case the tool is equipped with a silencer, make sure that this silencer is working properly, a damaged silencer has
to be replaced.
The tool should be maintained regularly to minimize the noise emission and occurring vibration.
If you intend not to use the tool for a longer period of time, it has to be oiled. Please fill some droplets of resin and
acid free oil into the air inlet and let the tool run free for a couple of seconds.
Maintain the tool at least yearly.
The user or the user's employer shall assess the specific use that can be present as a result of each use.
Never use the tool otherwise than the tool is designed for and as explained in this manual.
Damages as a consequence of not following this manual, or caused by incorrect use or incorrect repairs, will never be
covered by our warranty and we will have no responsibility for it. We reserve the right for technical improvements,
without prior notification.
This tool is designed for spraying oils, solvents, coatings and liquids. If used otherwise a risk assessment has to be
made by the employer/user.
Immediately shut down the equipment in case you hear unusual noises, or if a sudden power drop occurs. Check the
pneumatic tool and the compressed air supply system.
Pneumatic tool
-
lubrication is insufficient
-
worn tool/accessory, not suitable for use or faulted
Compressed air supply system
-
compressor pressure is insufficient
-
pressure regulator not set on the correct pressure level, suitable to the tool being used.
-
there is a leak from the connection hose or from the connections (use Teflon tape or sealant paste)
-
leaks in the pneumatic system
-
filter or lubricator cogged
-
hose is crushed, pierced or too long (loss of pressure)
Any warranty is expressly waved in case of damages arising out of regular wear, overload, handling or use not
suitable for the tool. For this warranty to be applicable, the tool should not be dismantled when returned to your
retailer.
This warranty covers replaced parts and labor for a period of 12 months from the date of purchase (a proof of
purchase such as invoice or receipt is required).
Any defect may be removed by replacing the tool or repairing it, as the case may be.