2. TRANSPORT / TEMPORARY STORAGE /

RETURNS / DISPOSAL

2.1 Receiving inspection

• When receiving goods, check the condition of the pumping station delivered.
• In case of damage, note the exact damage and immediately notify the retailer in writing.

2.2 Transport

Pumping station falling over.
Risk of injury if the pumping station falls !
• Transport the pumping station in a vertical position.
• Never hang up the pumping station by the electric cable.
• Use a suitable means of transport.
• The pumping station has been inspected to make sure there is no damage due to transport.
• Choose a suitable means of transport according to the weight table.
Weight of the pumping station
SANIPUMP
with 10 meters of cable and float
®

2.3 Disposal

At the end of its life, this product must be returned to a dedicated collection point.
• It cannot be treated as household waste.
• Ask your local council about where to take the old appliance so that it can be recycled or
destroyed.

3. DESCRIPTION

3.1 General description and method of operation

SANIPUMP
is a waste water pumping station specially developed for private and commercial
®
use. It is not intended for pumping rainwater. It can be installed in an outdoor sump (pumping grey
water and black water).
SANIPUMP
with a vortex impeller can be installed in an outdoor sump (pumping grey water and
®
black water) or inside a building (pumping of grey water only).
The SANIPUMP
macerator has to be installed in a closed tank or a closed
®
sump to prevent danger associated with blades.
Weight
13 kg