Attention: when fi rst turned on the product executes the auto-calibration of the hygrostat. It is possible that during this
phase the "EXTRACTION" function will be activated to bring the room's humidity below the level required for this auto-ca-
libration.
Response:
Light impulse on activation of the H1 value (RH: 40%)
Light impulse on activation of the H2 value (RH: 55%)
Light impulse on activation of the H3 value (RH: 70%)
F: Direction of airfl ow (function can be activated if there are at least 2 units or multiple coupled units)
By pressing the "DIRECTION OF AIRFLOW" button the units generate an airfl ow that provides intake only and extraction
only simultaneously for the desired time, always keeping the atmosphere balanced. According to the button pressed, the
air intake and extraction direction can be reversed.
Attention: ethe sensors are not active in this function.
Attention: the speed can be modifi ed through the V commands pressed previously to those F.
Response:
Light pulse on activating the mode
Periodic light pulse (every 1 min.) active mode
I : Air intake function
By pressing the "AIR INTAKE FUNCTION" the product intakes air. In the case of several units, all of them intake air simul-
taneously until another command is given by the user.
Attention: the sensors are not active in this function.
Response:
Light pulse on activating the mode
Periodic light pulse (every 1 min.) active mode
E: Air extraction function
By pressing the "AIR EXTRACTION FUNCTION" the product extracts air. In the case of several units, all of them extract air
simultaneously until another command is given by the user.
Attention: the sensors are not active in this function.
Respuesta:
Light pulse on activating the mode
Periodic light pulse (every 1 min.) active mode
FILTER ALARM RESET
Every 2000 hours of operation the indicator light at the bottom right will emit a continuous red light signal. The product will
continue to operate by keeping the last command received.
To reset the hour counter inside the unit, press the key sequence detailed below (refer to the image of the remote control
on page 1):
PRODUCT RESET
This paragraph details the procedure for resetting the product, restoring it to the factory confi guration.
Every time the unit is turned on (except the fi rst), the product's red light will stay on for 10 seconds, if the (S) key is pressed
5 times in this interval the led will stay on until the product is turned off by means of Switch 0/1.
At this point the unit will be reset.
In the RESPIRO 100 RD / RESPIRO 150 RD version on the next turn-on it will become Master or Slave based on the wiring
executed.
38
HI - HI - H2- H2- H3- H3
1 Red
2 Red
3 Red
2 Red / 3 seg. / 2 Red
Red
1 Red / 3 seg. / 1 Red
Red
1 Rojo / 3 seg. / 1 Rojo
Rojo
|||
|||
|||