LIST COMMANDS
S
Surveillance function
A
Automatic mode
V
Speed selection
H
Selection of relative humidity threshold
F
Direction of airfl ow
I
Air intake function
E
Air extraction function
COMMANDS INSTRUCTIONS
S: Surveillance function (standby mode)
By pressing the "SURVEILLANCE" button, the product stays in standby mode with the damper closed but with the sensors
active. If the remove humidity parameters should exceed those set, the product automatically starts extracting the air at the
maximum speed until the values are restored and then returns to standby mode. In the case of several units, all the units
go into SURVEILLANCE mode. This function is very useful if the user is absent for long periods.
Response:
Light pulse on activating the mode
Periodic light pulse (every 1 min.) active mode
Constant light pulse Beyond Threshold value
A: Automatic mode
Automatic mode provides operation at 70 seconds in air extraction and 70 seconds in air intake at average speed.
By pressing the "AUTO" button, the product executes the automatic control of the active sensors (twilight, hygrostat); in the
case of values beyond the set threshold, the product will extract the air from the room at maximum speed until the thres-
hold value is restored. In the case of several units, all the units go into AUTOMATIC mode.
The product is fi tted with a twilight sensor that when the light intensity falls reduces the operating speed to the minimum
to reduce the noise generated by the air.
Response:
Light pulse on activating the mode
Periodic light pulse (every 1 min.) active mode
Constant light pulse Beyond Threshold value
V: Speed selection
By pressing the "SPEED SELECTION" commands, the unit goes into manual mode enabling the desired speed to be defi ned,
keeping it working at 70 seconds in air extraction and 70 seconds in air intake. In the case of several units, all the units work
at the selected speed.
Attention: the sensors are not active in manual mode.
Response:
Light pulse on activation of speed 1
Light pulse on activation of speed 2
Light pulse on activation of speed 3
H: Selection of relative humidity threshold
It is possible to change the hygrostat trigger point threshold to adapt the value to the type of environment where it is insta-
lled. Once the relative humidity value set has been exceeded, the unit continuously extracts air at the maximum speed until
the relative humidity read returns to below the set value. In the case of several units, all the products extract air until the
set threshold is reached. The default set value is "Level H2", which corresponds to RH=55%.
S
V3
H3
V2
H2
V1
H1
A
F1
F2
I
E
Red
White/Red
Red
White/Red
Ninguno
Red
1 White
2 White
3 White
37