Functions:
Calibration (Press Cal Key for 3 Seconds):
CAL
Select the calibration routine pH or Redox by Up or Down key.
o
ENT
Standard Routine calibration pH probe is 7 and 4 buffer solution and Redox 465 mV buffer
o
solution
Set Point (Press Mode Key):
Press Mode Key and choose SetPoint and adjust value with Up or Down Key before press
o
ESC
Enter and confirm.
MODE
prog
Press Cal and Mode Key (both) for 5 Seconds and run Program Setup:
Program Menu (Press Enter to Mode the following Item)
o
CAL
ENT
ESC
MODE
Save and escape Program setup with ESC key
Exit
o
Priming Pump Keep Press UP Key for 1 seconds and priming redox pump
priming 700mv
o
Priming Pump Keep Press Down Key for 1 seconds and priming pH pump
priming 7.2ph
o
Lock pump function
Press Up and Enter (both) after 5 second flash Rx Stop press again to unlock
o
Press Down and Esc (both) after 5 second flash pH Stop press again to unlock
o
The unit doses in proportional mode respect at Set Point (minimum distance 25%, maximum
distance 90% of 10 minutes time period dosing)
Note: The unit in program menu to go out in automatic mode after 1 minutes of wait time, the unit
doesn't save nothing.
0000137934
Instruction Setting
§
Sp 750mv 700 mv
§
Sp 7.4ph
7.6 ph
§
Language_ (It's possible to have 5 language EN, IT, SP, DE, FR)
§
Redox Measure
Setpoint 750 mv (Adjust value with enter and up or down key) It's possible
to adjust from 0 to 1000 mV value for Redox
Sp type low (Adjust value LOW or HIGH)
Ofa time 000 min (Adjust value OFF or set Time)
Alarm band 000 rx (Adjust value from 100 to 300 mV )
Type PROP (Adjust value between OFF, PROP, ON/OFF or TIMED)
(only if set to Timed there are two new entries to make a dosage cycles ON
/ OFF selectable)
§
Timed ON (Change the value from 1 to 120 minutes)
§
Timed OFF (Change the value from 1 to 120 minutes)
§
ph Measure
Setpoint 7.4ph (Adjust value with enter and up or down key) It's possible to
adjust from 0 to 14 pH value.
Sp type acid (Adjust value ACID or ALKA)
Ofa time 000 min (Adjust value OFF or set Time)
Alr band 000 ph (Adjust value from 1 pH to 3 pH)
Temp 25*C(Adjust value with enter and up or down key) pH measure only.
Type PROP (Adjust value between OFF, PROP or ON/OFF )
§
Flow (Adjust value with enter and up or down key Enable or Disable)
It's possible to enable(ON) or disable (OFF) signal input
§
Calibration probe (Adjust value with enter and up or down key)
Full (pH 7 and 4, Redox 465 mV buffer solution)
Easy (pH 7, Redox 465 mV buffer solution)
Off (Disabled)
§
Password (Adjust value with enter and up or down key, standard value 0000)
save (Adjust value with up or down key and confirm with enter key)
rev. 1.0
CAL
ENT
2
Tabla de contenido
loading

Tabla de contenido