7. Warnings
• The filter in SR 99-1 must always be depressurized before the
filter element is changed or other work is done on the filter.
• If the power supply cable is to be changed or if other work is to
be done on the electrical distribution box, this may be done only
by a person who has the necessary knowledge. Get in touch
with your distributor or with Sundström Safety AB.
8. Technical data.
Particle collecting capacity
The class A3P3 filter element collects more than 99.99% of all
particles at a flow rate of 95 l/min and using paraffin oil as the test
aerosol (EN 143:2000).
Collection of gases/vapours
The class A3P3 filter element can adsorb 100–150 grams of oil
before it is saturated (EN 14387:2004).
Supply pressure
6–10 bar (600–1,000 kPa).
Air flow rate
Max. 900 l/min.
Supply pipe
The supply pipe to the compressed air filter must have an inside
diameter of at least 11 mm to ensure that it can deliver the maxi-
mum air flow rate.
Compressed air supply tube
The following tubes are type approved together with all Sundström
compressed air fed equipment.
• SR 358. 9.5/15 mm plastic tube, made of polyester reinforced
PVC. Oil and chemicals resistent. 5–30 m.
• SR 359. 9.5/18 mm rubber tube, made of EPDM/Polyester.
Antistatic, heat resistant. 5–30 m.
• SR 360. 8/12 mm plastic spiral coiled tube made of Polyurethane.
2, 4, 6 and 8 m.
14
9. Components. Fig. 1
No. Description
1. Mounting nut, filter regulator
2. Inlet
3. Filter regulator, automatic drain
4. Seal, drain bowl
5. Drain bowl
6. Pre-collector element
7. Pre-collector
8. Hose with couplings
9. Control knob, filter regulator
10. Pressure gauge
11. Outlet
12. Safety coupling female 1/2"
Compressed air tube. See 8. Technical data
13. Particulate filter
14. Activated carbon
15. Filter housing
16. Knob
17. Set of seals for filter housing
18. Y coupling
19. SR 292 Filter element
Ordering No.
R03-2809
-
R03-2801
R03-2806
R03-2808
R03-2805
R03-2804
R03-2605
R03-2803
R03-2108
-
R03-2103
-
-
-
R03-2607
R03-2604
R03-2127
R03-2001