OPERATION

WARNING
The correct use of the electric
compressor consists in alternating
running, that is for 60% of the total
time in operation.
The electric compressor is
provided with a safety valve adjusted
at a pressure superior to the maximum
pressure of the air pressure switch.
It is released in case of malfunction
of the air pressure switch and opens
an outlet for exceeding air (fig. 7.5) .
The customer is not entitled to
adjust the compressor so that it can
exceed the maximum pressure
written on the tank label.
While the compressor is in
operation and until a few minutes
after switching it off, do not touch the
pipes, the head, the motor, the check
valve nor any part of the compressor
which is subject to heating.
You might get burned.
CORRECT USE OF COMPRESSED AIR
To use compressed air correctly, please act
as follows (fig. 6-7) :
adjust the desired pressure by rotating
the adjuster knob 7.4 : pull the knob and
rotate it clockwise to increase the
pressure, or in the opposite direction to
reduce the pressure.
Then push the knob downwards to block
it. The adjusted pressure will be
indicated on the manometer 6.1 ,
GB
whereas the value shown on the
manometer 6.2 refers to the inner tank
pressure;
connect the pipe of the machine tool to
be used to the air outlet tap 7.3 and open
the tap. After using the compressor close
the tap again.