Honeywell HumidiPRO H6062 Instrucciones De Instalación página 19

Ocultar thumbs Ver también para HumidiPRO H6062:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Caution
Electrical Shock Hazard. Can cause
electrical shock or equipment damage.
Disconnect power supply before connecting wiring.
Wiring must comply with applicable
codes, ordinances and regulations:
1. Wire the C7089 Outdoor Sensor to the
S terminals on the humidity control. If
leadwire provided with C7089 is not
long enough (60 in.), run a cable to a
hole at C7089 location.
• Using color-coded, 18-gauge,
shielded thermostat wire is
recommended. For example of
general wiring of C7089, see image
at right.
• Pigtail wiring can be used.
2. Mount C7089 in its mounting clip.
3. Plug wiring hole using nonhardening
caulk or putty.
1
C7089
1
USE APPROPRIATE MOUNTING MEANS FOR THE
TYPE OF STRUCTURE.
2
PLUG WIRING HOLE WITH NON-HARDENING
CAULK OR PUTTY.
19
WIRING HOLE
THROUGH
STRUCTURE
C
R
U
U
S
S
2
M34611
Tabla de contenido
loading

Tabla de contenido