Working Advice; Maintenance And Service; Maintenance And Cleaning; After-Sales Service And Application Service - Bosch GBH Professional 240 Manual Original

Ocultar thumbs Ver también para GBH Professional 240:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
OBJ_BUCH-2460-003.book Page 18 Monday, April 24, 2017 10:03 AM
18 | English

Working Advice

 Before any work on the machine itself, pull the mains
plug.
 Hold the tool by the insulated gripping surfaces when
performing operations where the application tool or
the screw could contact hidden wiring or its own power
cord. Contact with a "live" wire will also make exposed
metal parts of the power tool "live" and shock the operator.
Changing the Chiselling Position (Vario-Lock)
The chisel can be locked in 36 positions. In this manner, the
optimum working position can be set for each application.
– Insert the chisel into the tool holder.
– Turn the mode selector switch 11 to the "Vario-Lock" posi-
tion (see "Setting the operating mode", page 17).
– Turn the tool holder to the desired chiselling position.
– Turn the mode selector switch 11 to the "chiselling" posi-
tion. The tool holder is now locked.
– For chiselling, set the rotation direction to right rotation.
Inserting Screwdriver Bits (see figure L)
 Apply the power tool to the screw/nut only when it is
switched off. Rotating tool inserts can slip off.
To work with screwdriver bits, a universal bit holder 28 with
SDS-plus shank (accessory) is required.
– Clean the shank end of the adapter shank and apply a light
coat of grease.
– Insert the universal bit holder with a turning motion into
the tool holder until it automatically locks.
– Check the locking effect by pulling the universal bit holder.
– Insert a screwdriver bit into the universal bit holder. Use
only screwdriver bits that match the screw head.
– To remove the universal bit holder, pull the locking sleeve
5 toward the rear and remove the universal bit holder 28
out of the tool holder.

Maintenance and Service

Maintenance and Cleaning

 Before any work on the machine itself, pull the mains
plug.
 For safe and proper working, always keep the machine
and ventilation slots clean.
 A damaged dust protection cap should be changed im-
mediately. We recommend having this carried out by
an after-sales service.
– Clean the tool holder 3 each time after using.
If the replacement of the supply cord is necessary, this has to
be done by Bosch or an authorized Bosch service agent in or-
der to avoid a safety hazard.

After-sales Service and Application Service

Our after-sales service responds to your questions concern-
ing maintenance and repair of your product as well as spare
parts. Exploded views and information on spare parts can al-
so be found under:
www.bosch-pt.com
1 609 92A 3SE | (24.4.17)
Bosch's application service team will gladly answer questions
concerning our products and their accessories.
In all correspondence and spare parts orders, please always
include the 10-digit article number given on the nameplate of
the product.
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham
Uxbridge
UB 9 5HJ
At www.bosch-pt.co.uk you can order spare parts or arrange
the collection of a product in need of servicing or repair.
Tel. Service: (0344) 7360109
Ireland
Origo Ltd.
Unit 23 Magna Drive
Magna Business Park
City West
Dublin 24
Tel. Service: (01) 4666700
Fax: (01) 4666888
Australia, New Zealand and Pacific Islands
Robert Bosch Australia Pty. Ltd.
Power Tools
Locked Bag 66
Clayton South VIC 3169
Customer Contact Center
Inside Australia:
Phone: (01300) 307044
Fax: (01300) 307045
Inside New Zealand:
Phone: (0800) 543353
Fax: (0800) 428570
Outside AU and NZ:
Phone: +61 3 95415555
www.bosch-pt.com.au
www.bosch-pt.co.nz
Republic of South Africa
Customer service
Hotline: (011) 6519600
Gauteng – BSC Service Centre
35 Roper Street, New Centre
Johannesburg
Tel.: (011) 4939375
Fax: (011) 4930126
Bosch Power Tools
Tabla de contenido
loading

Este manual también es adecuado para:

Gbh professional 240 f

Tabla de contenido