Trouble Shooting
Problem
Motor doesn't start
Piezo doesn't ignite
No gas at burner
Burner ignites, flame is
extinguished as soon as the gas
valve is released
-
Burner goes out while in use
Important!
Have repairs carried out only by specialist workshops or ISC.
06.11.2001 13:53 Uhr
Cause
No electricity
Electrode incorrectly adjusted
- Gas valve is closed
- Gas cylinder is empty
- Gas hose or connection leaks
- The thermoelement was not
-
warm enough
- The safety thermostat
-
switches off
- Gas flow too high
- Air input too low
Seite 9
Remedy
- Check electrical outlet
- Check mains cable
Check electrode and precisely
set according to diagram
- Open valve
- New gas cylinder
- Locate point of leak with soap
-
foam and repair
- Repeat ignition procedure
-
while pressing in the gas
-
valve knob
- Allow the heater to cool for a
-
few minutes and reignite
- Have the pressure regulator
-
inspected and replace if
-
necessary
- Check the suction grid and
-
clean
- Inspect ventilator
GB
9