Burner Input Requirements; Electrical Requirements; Grounding Instructions - Whirlpool 7MWGD1860EM0 Instrucciones De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Dryer gas pipe
The gas pipe that comes out through the rear of your dryer
has a 3/8" male pipe thread.
29" Wide Model
A
A. 3/8" NPT dryer pipe
A
A. 3/8" NPT dryer pipe
27" Wide Model
3
"
*5
/
4
(146 mm)
A. 3/8" NPT dryer pipe
A. 3/8" NPT dryer pipe

Burner input requirements

Elevations up to 10,000 ft. (3,048 m):
The design of this dryer is certified by CSA International for
use at altitudes up to 10,000 ft. (3,048 m) above sea level at
the B.T.U. rating indicated on the model/serial number plate.
Burner input adjustments are not required when the dryer is
operated up to this elevation.
Elevations above 10,000 ft. (3,048 m):
When installed above 10,000 ft. (3,048 m), a 4% reduction
of the burner B.T.U. rating shown on the model/serial
number plate is required for each 1,000 ft. (305 m)
increase in elevation.
Gas supply pressure testing
The dryer must be disconnected from the gas supply piping
system during pressure testing at pressures greater than
1/2 psi.
22
1¼"
(32 mm)
9¼"
(235 mm)
1¼"
(32 mm)
9¼"
(235 mm)
A
1
1
"
/
2
(38 mm)

Electrical Requirements

110 - 127 Volt, 60 Hz., AC only, 15- or 20-amp fused
electrical supply is required. A time-delay fuse or circuit
breaker is recommended. It is also recommended that a
separate circuit serving only this dryer be provided.

GROUNDING INSTRUCTIONS

For a grounded, cord-connected dryer:
I
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a quali ed electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not t the outlet, have a proper outlet
installed by a quali ed electrician.
SAVE THESE INSTRUCTIONS
Tabla de contenido
loading

Tabla de contenido