1. General information
1.1 System description
The Sundström SR 584 welding shield is intended for use
together with the Sundström SR 580 Helmet with visor and
with the Sundströms battery-powered fan SR 500/SR 700 or
compressed air attachment SR 507.
1.2 Applications
The SR 584 in combination with the SR 580 and fan/
compressed air is designed specifically for protection against
harmful gases, radiation and spatter during welding, flame
cutting, grinding and similar work. The design of the combination
makes it usable for work in confined and inaccessible areas.
1.3 Warnings Limitations
Warnings
• Change the lens immediately if it is found to be damaged.
• Materials that come into contact with the user's skin may give
rise to allergic reactions if the user is sensitive.
• The outer, hinged holder for protective lens must be fully
lowered while work is in progress.
• If the welding shield is equipped with a toughened mineral
glass lens, a protective lens should be fitted on the inside of it.
• Damaged or scratched occulars must immediately be replaced.
Limitations
• Check that the welding filter have the correct scale number
for your work.
• The welding shield must always be fitted with a protective
lens in addition to the welding filter.
• Always observe the fire safety rules.
2. Parts
Description
Frame, welding shield
Adapter right+left
Knob complete
Lock device welding lens
Welding lens, shade No. 8, SR 59008
Welding lens, shade No. 9, SR 59009
Welding lens, shade No. 10, SR 59010
Welding lens, shade No. 11, SR 59011
Welding lens, shade No. 12, SR 59012
Welding lens, shade No. 13, SR 59013
Automatic lens. EN 3/10, SR 59005
Automatic lens. EN 3/11, SR 59006
Automatic lens. EN 4/9-13, SR 59007
Inner protective lens for automatic lens
Correction lens, dptr 1,0, SR 59014
Correction lens, dptr 1,5, SR 59015
Correction lens, dptr 2,0, SR 59016
Correction lens, dptr 2,5, SR 59017
Spring for welding lens
Protective lens PC
Holder protective lens
Welding shield SR 584
Ordering No.
R06-0816
R06-0820
R06-0821
R06-0819
T06-4001
T06-4002
T06-4003
T06-4004
T06-4005
T06-4006
T06-4007
T06-4008
T06-4009
R06-4009
T06-4010
T06-4011
T06-4012
T06-4013
R06-0818
R06-4008
R06-0817
Neck and chest protection
Face seal
Protective hood
Protective hose for the breathing hose
3. Use
3.1 To fit the welding shield on the helmet
• Remove knobs and washers from the helmet. Fig. 1.
• Mount the welding shield on the helmet. Fig. 2.
3.2 To remove the welding shield
Remove the welding shield. Fig. 3. (Replace the washers and
knobs on the helmet.)
3.3 Welding lens
For replacement of welding lens. See 4.3.2.
3.4 Donning/Doffing the helmet
Follow the directives in the user instructions for the SR 580
helmet.
4. Maintenance
The person responsible for cleaning and maintaining the
equipment must have suitable training and be well acquainted
with work of this type.
4.1 Cleaning
Clean welding visor and glass with Sundström SR 5226
cleaning wipes or with a mild soap solution.
If necessary, spray the welding shield with 70 % ethanol or
isopropanol solution for disinfection.
NOTE! Never use a solvent for cleaning!
4.2 Storage
After cleaning, the equipment should be stored in a dry and
clean location at room temperature. Avoid direct sunlight. The
welding shield is not affected by an extended period of storage.
4.3 Changing parts
4.3.1 To change the protective lens
The lens must be CE marked and of standard 90x110 mm size.
• Remove the old protective lens. Fig. 4, 5, 6.
• Fit a new protective lens. Fig. 7, 8, 9, 10.
4.3.2 To change the welding lens
The lens must be CE marked and of standard 90x110 mm size.
Welding lens
• Remove the old welding lens. Fig. 11, 12, 13, 14.
• Fit a new welding lens in the reverse order. Fig. 14, 13, 12, 11.
Automatic lens
• Remove the old automatic lens. Fig. 15, 16.
• Fit a new automatic lens in the reverse order. Fig. 16, 15.
4.3.3 Fitting the correction lens
• Place the correction lens on the inside of the welding lens.
5. Technical specifications
Temperature range
• Storage temperature: from -20 °C to +40 °C at a relative
humidity below 90 %.
• Service temperature: from -10 °C to +55 °C at a relative
humidity below 90 %.
EN
T06-8011
T06-8012
T06-4014
T06-4016
13