4. Product Information

4.1 Intelligent technology

Urinal installations in the public and semi-public sector must satisfy very stringent
requirements - hygiene, reliability and low cleaning/maintenance costs are the pri-
mary concern.
The DuraStyle urinal satisfies these requirements: The urinal offers touchless flush-
ing thanks to an electronic control unit developed especially by Duravit. The electron-
ics operate in conjunction with an infrared sensor that automatically detects arrival
of a user and subsequently initiates flushing when the user moves away from the
urinal (detection time/dwell time 9 sec.). Since the DuraStyle urinal thinks logically,
passersby or even objects that remain stationary within the detection range of the
controls for some time do not trigger spurious flushing - the unit adjusts continu-
ously to the surrounding conditions. In addition, the DuraStyle urinal offers several
free selectable service and flushing programs as well as a manually adjustable flush
duration. Automatic flushing every 12 hours to maintain hygiene prevents the build-
up of unpleasant odours.

4.2 User-friendly maintenance

The DuraStyle urinal is especially easy to service and maintain - the control unit is
maintenance-free; the solenoid valve is replaced with little effort after removing the
stainless steel cover beneath the control unit. Both the pre-shutoff valve and the dirt-
collecting screen can be accessed easily without having to remove the stainless steel
cover. The battery can be exchanged after removing the vandal-proof control unit in
just a few quick steps and then replacing it.

4.3 Factory settings (defaults)

Detection time/dwell time:
Flush duration (full flush):
Flush duration (reduced flush):
Please refer to section 5.4.1 for information on manually adjusting the flush duration
(min. 5 sec., max. 20 sec.).
9 sec.
7 sec.
50% of full flush, but min. 5 sec.