Grounding the Generator

To avoid electrocution, this generator must be properly grounded prior to use. For instructions see Control Panel Functions
page 9.

Standard Atmospheric Conditions

Ambient Temperature: 77ºF (25ºC)
Barometric Pressure: 100kPa
Relative Humidity: 30%
Generator output will vary due to changes in temperature, altitude, and humidity. If the temperature, humidity, or altitude are
higher than standard atmospheric conditions, the generator's output will be reduced. The load attached to the generator
must therefore be reduced.

Starting the Engine

Place generator on a level surface. All electrical loads MUST be disconnected from
generator.
Turn the ENGINE ECONOMY SWITCH to "OFF"
Turn the fuel cap Air Vent to the "ON" position.
Turn the 3 in 1 Start Switch to "CHOKE"
Pull recoil handle (starter cord) slowly until resistance is felt, then pull rapidly.
Let engine run for several seconds and then gradually, as engine warms up, turn the
3 in 1 Start Switch to the "ON" position.
Starter pull cord recoils rapidly and can cause
injury. To avoid injury, pull starter cord slowly until
resistance is felt, then pull rapidly.
Note: To start the generator with the ENGINE ECONOMY SWITCH in the "ON" position
Disconnect all electrical loads from generator.
If ambient temperature is below 32ºF (0ºC) allow 3 minutes for the engine to warm up.
The ENGINE ECONOMY SWITCH is in "ON" position, the unit returns to normal operation after the above warm up
time.
ENGINE ECONOMY SWITCH must be turned to the "OFF" position when using electronic devices that require a
large starting current, such as a compressor.