Precautions During Maintenance Operations - SystemAir SYSCROLL Air Serie Manual De Instalación Y De Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

periodically check the board's internal wiring
do not use cables having an inadequate section or flying
connections, even for limited periods of time or in an emergency
Prevention of other residual risks
make sure that the connections to the unit conform to the
instructions provided in this manual and on the unit's panelling
if you have to disassemble a piece, make sure that it has been
properly mounted again before restarting the unit
do not touch the delivery pipes from the compressor, the
compressor and any other piping or component inside the
machine before wearing protective gloves
keep a fire extinguisher fir for electrical appliances near the
machine
on the units installed indoor, connect the safety valve of the
refrigeration circuit to a piping network that can channel any
overflowing refrigerant outside
remove and leak of fluid inside and outside the unit
collect the waste liquids and dry any oil spillage
periodically clean the compressor compartment, to remove any
fouling
do not store flammable liquids near the unit
do not disperse the refrigerant and the lubricating oil into the
environment
weld only empty pipes; do not approach flames or other sources
of heat to refrigerant pipes
do not bend/hit pipes containing fluids under pressure

2.6 Precautions during maintenance operations

Maintenance operations can be carried out by authorised technicians
only.
Before performing any maintenance operations:
disconnect the unit from the mains with the external disconnecting
switch
2 - Safety
place a warning sign "do not turn on - maintenance in progress"
on the external disconnecting switch
make sure that on-off remote controls are inhibited
wear suitable personal protective equipment (helmet, safety
gloves, goggles and shoes etc.)
To carry out any measurements or checks which require the
activation of the machine:
work with the electrical board open only for the necessary time
close the electrical board as soon as the measurement or check
has been completed
for outdoor units, do not carry out any operations in the presence
of dangerous climatic conditions (rain, snow, mist etc.)
The following precautions must be always adopted:
do not scatter the fluids of the refrigeration circuit in the
surrounding environment
when replacing an eprom or electronic cards, use always suitable
devices (extractor, antistatic bracelet, etc.)
to replace a compressor, the evaporator, the condensing coils or
any other weighty element, make sure that the lifting equipment is
consistent with the weight to be lifted
in air units with independent compressor compartment, do not
access the fan compartment unless you have disconnected the
machine by the disconnecting switch on the board and you have
placed a warning sign "do not turn on - maintenance in progress"
contact manufacturer for any modifications to the refrigeration,
hydraulic or wiring diagram of the unit, as well as to its control
logics
contact manufacturer if it is necessary to perform very difficult
disassembly and assembly operations
use only original spare parts purchased directly from manufacturer
or the official retailers of the companies on the recommended
spare parts list
contact manufacturer if it is necessary to handle the unit one year
after its positioning on site or if you wish to dismantle it.
5