Operating Instructions Contact E und Contact E duo/hot
5. Modification of the units, handpieces and probe shapes is exclusively at the operator's own responsibility.
6. interventions lead to loss of warranty and exclusion of liability.
7. Do not use solvents to clean the devices.
8. When returning the instrument - e.g. for repair purposes - pack it unbreakable
4.
Operating instructions:
4.1. Before commissioning:
Our waxers comply with the state of the art and the recognized safety regulations, nevertheless dangers
can arise if the device is not handled properly.
- Only operate the device in perfect condition and in compliance with the operating instructions!
- Observe recognized rules for occupational safety.
- Use by qualified personnel only
- Check the device for technically perfect condition, especially all cables and the housing.
- place the modelling tip(s) required for the next working step on the heating rod
Attach to the handpiece ( plug connection )
- Attach the holding clamp, art. no. 410-1002, to the device/table and always keep the handpiece there after
use deposit/clamp
a – Modelling Tip
d - Magnetic Rings
4.2. 4.2 Operation:
1. establish mains connection (only connect to approved sockets)
2. remove the dust cover of the Contact E variants and insert the desired wax chip quality ...and equip it.
3. connect Contact E devices to the power supply. They are ready for use after a short heat-up time. The
temperature is controlled by the rotary control/potentiometer located on the top of the metal plate. The
desired temperature can be controlled separately for each handpiece. Turning the knob to the left
decreases the temperature, turning the knob to the right increases the temperature.
All Contact E versions have a black slide switch on the back of the unit. This allows the limited heating for
the left half of the plate to be switched on or off. The LED on the left side of the unit indicates when the
heating is switched on when it is red, but also when the heating is still in the heating phase up to the set
temperature. The colour green indicates that the maximum factory-set temperature has been reached.
Contact hot is not equipped with additional handpieces and is used for processing with instruments and
separate heat source.
4. pick up wax with the hot tip and place liquid wax drops on the wax crown.
5. use a suitable tool to change the hot tips - danger of burning!
6. if you do not need your device for a longer period of time, please switch it off and always place the handpiece in
the intended holding clamp off - danger of burns !
After having removed the protective foil of the adhesive tape, the holding clamp can be placed anywhere on the
Take the cable lengths of the handpieces into account.
7. switch off the device when leaving the workplace - danger of burns! Put on the dust cover
8. final storage or packing of the equipment only after complete cooling.
5. Disposal:
When disposing of the device, the applicable legal regulations must be observed.
6. Garantie:
The company YETI repairs the waxer 24 months from delivery date free of charge
as far as it concerns damages due to material defects or manufacturing defects !
Excluded from this are wearing parts like handpieces and modelling probes.
Document:
Created on/by:
BA
04.06.2020/TB
b – Heating Element
e – handpiece
modified on/by:
09.10.2017/ST
c - Handle
d- Cable
Revision:
0
released on/by:
Page number:
09.06.2020/QM
Seite 2 of 4