John Bean B 800 Manual Del Operador página 146

Tabla de contenido
146
Setting Parameters
Resolution of the unbalance amount readings
Resolution of the unbalance amount readings
Selecting the resolution of unbalance readings
Selecting the resolution of unbalance readings
in 1 or 5 g, or 0.05 or 0.25 oz increments.
in 0.05 / 0.25 oz or 1 / 5 g, increments.
Normal* =
Normal* =
0.25 oz (5 g) increments
5 g (0.25 oz) increments
Fine
Fine
=
=
0.05 oz (1 g) increments
1 g (0.05 oz) increments
The selected mode of operation can be
The selected mode of operation can be
transferred to the permanent memory.
transferred to the permanent memory.
Suppression of minor unbalance amount
Suppression of minor unbalance amount
readings
readings
Off
Off
=
=
Suppression off
Suppression off
On *
On *
=
=
Suppression on
Suppression on
The selected mode of operation can be
The selected mode of operation can be
transferred to the permanent memory.
transferred to the permanent memory.
Setting threshold value for unbalance
Setting threshold value for unbalance
suppression in oz or gms
suppression in g
Selecting the limit (threshold) value for suppression
Selecting the limit (threshold) value for
of minor unbalance readings in grammes, or
suppression of minor unbalance readings
ounces. The unit (oz or gms) depends on the
in grammes, or ounces. The unit (gms or
settings made under "Measurement limit of the
oz) depends on the settings made under
unbalance amount readings".
"Measurement limit of the unbalance amount
readings".
Ounces:
Grammes:
Range 0.25 to 2.00 oz
Range 3.50 to 20.0 g
Factory–adjusted to 0.25 oz
Factory–adjusted to 3.5 g
Grammes:
Ounces:
Range 5 to 20.0 g
Range 0.25 to 2.00 oz
Factory–adjusted to 5 g
Factory–adjusted to 0.25 oz
The selected mode of operation can be
The selected mode of operation can be
transferred to the permanent memory.
transferred to the permanent memory.
Measurement limit of the unbalance amount
Measurement limit of the unbalance amount
readings
readings
Selecting unbalance readings in grammes or
Selecting unbalance readings in grammes or
ounces, active when the machine is switched on.
ounces, active when the machine is switched on.
Ounces*
=
Gramm *
=
Gramm
=
Readings in grammes
The selected mode of operation can be
Ounze
=
Readings in ounces
transferred to the permanent memory.
The selected mode of operation can be
transferred to the permanent memory.
Number of turns
5 to 25 revolutions possible.
Number of turns
*
Factory–adjusted to 10.*
5 to 25 revolutions possible.
Factory–adjusted to 10.*
The selected mode of operation can be
transferred to the permanent memory.
The selected mode of operation can be
transferred to the permanent memory.
Note
Reducing the number of measurement revolutions
Note
will reduce the accuracy of measurement.
Reducing the number of measurement revolutions
will reduce the accuracy of measurement.
* = Factory adjusted mode
........
Readings in ounces
Readings in grammes
Tabla de contenido
loading

Tabla de contenido