SUPPLEMENTARY INFORMATION
Pressing the '+' and '-' buttons simultaneously provides access to additional data from
the last process. You can then leaf through the information using the '+' or '-' button.
When the battery is disconnected from the charger, the Start display reappears; this era-
ses all the current data, and it cannot be called up again.
11.
ERROR MESSAGES
The Power Peak ULTIMATE 2 is equipped with a range of safety features to ensure that
charge and discharge processes are completed reliably. As soon as an error occurs, an
appropriate message appears on the screen, and the piezo buzzer emits a shrill warning
sound.
If any of the following error messages appear, you should first eliminate the problem and
then press any button to erase the message.
Operating instructions
POWER PEAK ULTIMATE 2
Display of input and output voltage
Display of maximum charge voltage and average
discharge voltage
Display of charged-in and discharged capacity only
Display of process duration
Parameters for the process just concluded
Input voltage outside the permitted range (11 - 15
Volts).
Charge or discharge process started with no batte-
ry connected: connect battery.
20
No.
8470