Operation
The test set must have a good 9V battery installed in order to operate.
1.
Connect the red wire to the ring (negative) side of the circuit.
2.
Connect the black wire to the tip (positive) side of the circuit.
3.
Use the Talk, Monitor and Mute features as described in this section.
Automatic Ground Start
Some lines, especially PABX, require a momentary ground to draw a dial tone.
Connect the test set's red and black wires to the telephone circuit as usual, and connect the
green wire to ground. Press the TALK button momentarily to check for dial tone.
The ground start is automatic, and the green wire can remain connected without affecting the
call.
TALK
Press once to go off-hook (connect). Press MONITOR to go on-hook (disconnect).
Off-Hook Mode
LED: Flashing red
Tone: Middle Pitch–Middle Pitch
On-Hook Mode
LED: Flashing red (First press)
Tone: Middle Pitch
LED: None (Second press)
Tone: Low Pitch
PE945