Visualisation Of Electronic Board Parameters On Boiler Display ("Info" Function) - Baxi Mainfour 240 F Manual Para El Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
20. VISUALISATION OF PARAMETERS ON THE DISPLAY ("INFO" FUNCTION)
i
Press "
" for at least 5 seconds to visualise certain boiler information on the display on the front panel of the boiler.
NOTE:
when the "INFO" function is enabled, the message "A00", alternating with the boiler delivery temperature,
is shown on the display (figure 12):
+/-
Press buttons
(
A00:
current DHW temperature (°C);
A01:
current external temperature (°C) (with external probe connected);
A02:
instantaneous % value of the gas valve control signal ;
A03:
power range (%) (MAX R);
A04:
heating setpoint temperature (°C);
A05:
current heating delivery temperature (°C);
A06:
DHW temperature setpoint value (°C);
A07:
flame signal % value (0-100%);
A08:
not used;
A09:
last error that occurred in the boiler;
This function remains active for 3 minutes. It is possible to interrupt the "INFO" function in advance by holding down
the button ( ) for at least 5 seconds, or turning off the power to the boiler.
INSTRUCTIONS FOR FITTERS
) to display the following information:
16
Figure 12
926.527.2 - EN
Tabla de contenido
loading

Tabla de contenido