Technical Data - AERMEC WSA Serie Manual Técnico De Instalación Y Mantenimiento

Enfriadora agua
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

WSA
WSA
COOLING ONLY
Cooling capacity:
Total input power
Evaporator water flow rate
Evaporator pressure drop
Condenser water flow rate
Condenser pressure drop
HEATING
Heating capacity
Total input power
Condenser water flow rate
Condenser pressure drop
Evaporator water flow rate
Evaporator pressure drop
ENERGY INDICES
EER
EEC
COP
EEC
ELECTRICAL DATA
Power supply
Total input current
Maximum current
Peak current
COMPRESSORS
Type
Number
Number per circuit
CAPACITY CONTROL
Capacity control (1)
EVAPORATOR
Type
Number
Hydraulic connections
CONDENSER
Type
Number
Hydraulic connections
SOUND DATA
Sound power
Sound pressure
DIMENSIONS - outdoor installation
Height (°)
Height (° - L)
Height (T)
Height (T - L)
Width
Length
WEIGHT empty
TECHNICAL DATA REFER TO THE NORM
EN14511 - 1 - 2 - 3
cooling
- Processed water temperature
- Condenser inlet water temperature
- ¨t
10
7
0701
0801
kW
179
213
kW
37
42
30790
36640
l/h
20
20
kPa
l/h
37150 43860 48500 60540 74130
27
27
kPa
kW
191
218
43
48
kW
32850 37500 42140 52980 64500 74650 84450 95810 107500 118160 131920
l/h
kPa
41
20
25460 29240 32510 40940 49710 57960 65360 74160 83420 92190 102340
l/h
12
12
kPa
4.84
5.07
W/W
B
A
4.44
4.54
B
A
V
cool
A
66
74
hot
A
73
82
FLA
124
144
A
LRA
A
225
264
no.
1
1
no./
1/1
1/1
no.
40-100 40-100 40-100 40-100 20-100 20-100 20-100 20-100 20-100 20-100 20-100
Std TV
%
Ele TV
%
25-100 25-100 25-100 25-100 12.5-100 12.5-100 12.5-100 12.5-100 12.5-100 12.5-100 12.5-100
no.
1
1
Type/ø
V/3"
V/3"
1
1
no.
V/3"
V/3"
86.0
86.0
dB(A)
dB(A)
54.0
54.0
mm
1775
1775
mm
1775
1775
2000
2000
mm
2120
2120
mm
mm
810
810
mm
2960
2960
1251
1301
kg
heating
- Processed water temperature
- Evaporator inlet water temperature
7 °C
- ¨t
30 °C;
- Sound pressure measured 10 m. away in the
5k
open, with direction factor Q=2 according to

TECHNICAL DATA

0901
1101
1402
1602
234
294
357
423
48
58
74
83
40250
50570
61400
72760
19
23
36
40
87030 97520 109280
26
31
50
55
245
308
375
434
56
70
86
97
19
24
36
39
12
14
22
24
4.88
5.07
4.82
5. 1 0
B
A
B
4.38
4.40
4.36
4.47
B
B
B
400V-3-50Hz
82
101
132
148
91
117
146
164
162
182
248
288
310
391
287
336
twin-screw
1
1
2
2
1/1
1/1
2/2
2/2
Plates
1
1
1
1
V/3"
V/3"
V/3"
V/3"
Plates
1
1
1
1
V/3"
V/3"
V/3"
V/3"
86.0
92.0
89.0
89.0
54.0
60.0
57.0
57.0
1775
1775
1975
1975
1775
1775
2120
2120
2000
2000
2050
2050
2120
2120
2120
2120
810
810
810
810
2960
3360
2960
2960
1357
1788
2028
2097
45 °C
10 °C;
5k
1802
2002
2202
470
529
588
97
106
115
80840
90980
101140 114040 122980
41
45
48
120920
58
62
67
491
557
625
111
126
140
42
46
50
25
27
29
4.85
4.97
5. 1 1
A
B
B
A
4.42
4.43
4.46
A
B
B
A
164
184
203
183
209
235
324
344
364
391
482
575
2
2
2
2/2
2/2
2/2
1
1
1
V/3"
V/3"
V/3"
1
1
1
V/3"
V/3"
V/3"
89.0
93.0
95.0
57.0
61.0
63.0
2005
1985
2065
2120
2120
2120
2050
2050
2065
2120
2120
2120
810
810
810
2960
3360
3360
2169
2598
3000
ISO 3744
- Sound power The AERMEC sound power
value is determined on the basis of measu-
rements taken in accordance with the ISO
9614-2 standard, in compliance with what is
required by the EUROVENT Certification
2502
2802
663
715
131
140
53
62
136570
147060
75
88
687
767
151
172
55
74
32
44
5.06
5. 1 1
A
A
4.55
4.46
A
A
233
233
257
258
430
430
575
575
2
2
2/2
2/2
1
1
V/3"
V/3"
1
1
V/3"
V/3"
95.0
95.0
63.0
63.0
2065
2065
2120
2120
2065
2065
2120
2120
810
810
3360
3360
3095
3108