Electrical Installation - Jandy VS FloPro VSFHP085AUT Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Jandy
VS FloPro™ Variable-Speed Pumps
®
NOTE
To prevent entrapment, the system must be built so
it cannot operate with the pump drawing water from only
one (1) main drain. At least two (2) main drains must be
connected to the pump when it is in operation. However, if
two (2) main drains run into a single suction line, the single
suction line may be equipped with a valve that will shut off
both main drains from the pump.
4.
The piping must be well supported and not forced
together where it will experience constant stress.
5.
Always use properly sized valves. Jandy Diverter
Valves and Ball Valves typically have the best flow
capabilities.
6.
Use the fewest possible fittings especially 90 degree
elbows. Each additional fitting or length of pipe
increases resistance to flow which makes the pump
work harder.
NOTE
If more than ten (10) suction fittings are needed, the
pipe size must be increased.
7.
Every new installation must be pressure tested
according to local codes.
Replacement of Existing Pump
Jandy VS FloPro pumps can easily replace several other
pumps: the Hayward
Super Pump
®
II™, Pentair
SuperFlo
, Pentair WhisperFlo
®
®
PlusHP (PHP), Jandy MaxHP (MHP), Sta-Rite
Glas, Sta-Rite Dura-Glas II, Sta-Rite Dyna-Glas™, Sta-
Rite Max-E-Glas
, Sta-Rite Max-E-Pro
®
SuperMax
.
®
To replace the Pentair WhisperFlo, Jandy PlusHP, or
Jandy MaxHP, use the VS FloPro's adjustable base. The
VS FloPro base (and its spacers) increase the total height
of the pump and the height of the suction side of the
pump. See Table 2 and Figure 3.
NOTE
The small base with adjustable spacers comes with
all VS FloPro models. The large base is sold separately
as an accessory (Jandy Part Number R0546400).
Table 2.
VS FloPro Dimensions
Base Configuration
1. Pump without Base
2. Pump with Small Base
3. Pump with Small Base and
Spacers
4. Pump with Small + Large
Base
Install Spacers into Small Base
1.
Using a hand cutter tool, cut the plastic bars
connecting the top and bottom sets of spacers, as
shown in Figure 4.
|
Installation & Operation Manual
, Hayward Super
®
, Jandy
®
Dura-
®
, and Sta-Rite
®
Suction
Pump
Side
Height
Height
7 3/4"
12 3/4"
8 7/8"
13 7/8"
9 1/8"
14 1/8"
10 3/4"
15 3/4"
ENGLISH
2.
Push the two (2) top spacers and two (2) bottom
spacers out of the base.
3.
Align the pins in the four (4) spacers with the holes
in the base and snap the spacers into place, as
shown in Figure 5.
Figure 4.
Cut Sets of Spacers Out of Base
Figure 5.
Snap Spacers into Place
3.2

Electrical Installation

Voltage Checks
The correct voltage, as specified on the pump data plate and
Table 3 on page 10, is necessary for proper performance
and long motor life. Incorrect voltage will decrease the
pump's ability to perform and could cause overheating,
reduce the motor life, and result in higher electric bills.
It is the responsibility of the electrical installer to provide
data plate operating voltage to the pump by ensuring
proper circuit sizes and wire sizes for this specific
application.
The National Electrical Code
requires all pool pump circuits be protected with a
ground-fault circuit interrupter (GFCI). Therefore, it is
also the responsibility of the electrical installer to ensure
that the pump circuit is in compliance with this and all
other applicable requirements of the National Electrical
Code (NEC) and any other applicable installation codes.
Failure to provide data plate voltage (within 10%)
during operation will cause the motor to overheat and
void the warranty.
Page 9
Cut
spacers
at X.
(NEC
, NFPA-70
®
®
®
CAUTION
)
Tabla de contenido
loading

Tabla de contenido