ENGLISH
No Base Required
Hayward
Option
Pentair
1
Sta-Rite
Small Base
Option
Hayward Super II™
Jandy PlusHP by Zodiac
2
Jandy Max HP by Zodiac
Small Base with Spacers
Option
Pentair WhisperFlo
3
Sta-Rite Dyna-Glas™
Small Base + Large Base
Sta-Rite Max-E-Pro
Option
Sta-Rite Dura-Glas
4*
Sta-Rite Dura-Glas II
Sta-Rite Max-E-Glas
Figure 3.
VS FloPro Pump and Base Options
Table 1.
Pipe Sizing Chart for Schedule 40 PVC
Pipe Size
Maximum Flow
Suction
(6 feet per second)
1½"
37 GPM
(38 mm)
(140 LPM)
2"
62 GPM
(51 mm)
(235 LPM)
2½"
88 GPM
(64 mm)
(333 LPM)
3"
136 GPM
(76 mm)
(515 LPM)
4"
234 GPM
(102 mm)
(886 LPM)

Installation Recommendations

1.
To help prevent difficulty in priming, install the
suction pipe without high points (above inlet
of pump - inverted "U"s, commonly referred to
in plumbing as an airlock) that can trap air. For
installations of equipment up to 100 feet (30 m)
Jandy
VS FloPro™ Variable-Speed Pumps
®
VS FloPro with Small Base
®
Super Pump
®
Pump
®
SuperFlo
®
Height
Suction
®
SuperMax
®
Side
Height
®
®
®
®
* Optional
®
(Order R0546400)
Maximum Flow
Discharge
(8 feet per second)
50 GPM
(189 LPM)
85 GPM
(322 LPM)
120 GPM
(454 LPM)
184 GPM
(697 LPM)
313 GPM
(1185 LPM)
|
Installation & Operation Manual
from the water, refer to Table 1, the pipe sizing
chart. For installations of equipment more than 100
feet (30 m) from the water, the recommended pipe
size must be increased to the next size.
2.
VS FloPro Pumps come equipped with unions on
both the suction and discharge ports. This feature
simplifies installation and service and eliminates
the possibility of leaks at threaded adapters.
3.
The VS FloPro Pump must be connected to at least
two (2) hydraulically-balanced main drains for each
pool pump suction line. Each drain (suction outlet)
assembly must be provided with covers and must be
listed or certified to the latest published edition of
ANSI
/ASME
A112.19.8, or its successor standard,
®
®
ANSI/APSP-16. The suction fittings of the main
drains must be at least three (3) feet (1 m) apart or at
different planes. The suction fittings can be a drain
and skimmer, two (2) drains, two (2) skimmers, or a
skimmer with an equalizer line installed. Check the
local codes for proper installation.