Technical data
Basic degassing equipment:
•
Control of the Servitec.
•
"DV" degassing valve, box-packaged.
•
Plastic sleeve with operating manual and electric wiring diagram (attached
to the Servitec).
The Servitec is pre-assembled and shipped on a pallet.
4.5
Optional equipment and accessories
The following optional equipment and accessories are available for this device:
•
Fillsoft/Fillsoft zero for softening/desalination of the make-up water from
the potable water supply system. Replacement of the softening and
desalination cartridges.
•
Fillset for make-up with water
–
Fillset with integrated backflow preventer, water meter, dirt trap,
and shut-ff for the "WC" make-up line
•
Fillset Impulse with FQIR+ contact water meter for make-up with water.
–
If the Fillset Impulse is installed, you can regulate the entire make-up
quantity and the soft water capacity of Fillsoft softening systems. The
operational reliability of the device is assured and prevents
automatic make-up during major water loss or small leaks.
5
T e chnical data
Note!
The following values apply for all systems:
–
Permissible operating temperature of the device:
–
Permissible inlet pressure for make-up:
–
Make-up capacity:
–
Separation level, dissolved gases:
–
Separation level, free gases:
–
Degree of protection:
5.1
El ectrical system
Power output
T y pe
(k W)
35
0.7
60
1.1
75
1.1
95
1.1
5.2
D i mensions and connections
We ight
T y pe
35
60
75
95
5.3
Operation
S y stem volume
T y pe
(100% water)
(m³)
35
up to 220
60
up to 220
75
up to 220
95
up to 220
26 — English
Power supply
F using
(V / Hz/ A)
(internal)
(A )
230 / 50
230 / 50
230 / 50
230 / 50
He ight
(k g)
(mm)
42
1030
40
1215
39
1215
40
1215
S y stem volume
(50% water)
(m³)
up to 50
up to 50
up to 50
up to 50
Vacuum spray degassing — 24.04.2020 - Rev. A
•
Fillset Compact for make-up
–
Fillset Compact with integrated system separator, dirt trap, and shut-
off for the "WC" make-up line.
•
Fillguard for conductivity monitoring
–
If the Fillguard is fitted, the capacity of the Fillsoft Zero desalination
cartridge can be monitored based on the conductivity.
•
Enhancements for the device controller.
–
Various controller information can be queried via the RS-485
interface and it can also be used to communicate with control
centres or other devices, see chapter 6.5.2.1 "Connecting the RS-485
interface" on page 30 .
•
Bus modules for the communication with control centres.
•
Profibus-DP.
•
Ethernet.
•
I/O module for standard communication.
•
Modbus RTU
•
Control Remote
•
Gas discharge measurement for optimised degassing operation.
Note!
Separate operating manuals are supplied with accessories.
90 °C
1.3 bar – 6 bar
Up to 0.55 m³/h
≤ 90 %
100 %
IP 54
Number of RS-485
I/O module
interfaces
10
1
10
1
10
1
10
1
Width
De pth
(mm)
(mm)
620
440
685
440
600
525
600
525
Working pressure
Pe rmissible operating
(ba r)
ga uge pressure
(ba r)
0.5 – 2.5
8
0.5 – 4.5
8
1.3 – 5.4
10
1.3 – 7.2
10
Control Unit
(V, A)
No
230, 4
No
230, 4
No
230, 4
No
230, 4
S e rvitec input
connections (system
a nd make-up)
Internal thread ½ "
Internal thread ½ "
Internal thread ½ "
Internal thread ½ "
S e tpoint overflow
v a lve
(ba r)
–
–
–
–
Noise level
(dB)
55
55
55
55
S e rvitec output
connection
Internal thread 1 "
Internal thread 1 "
Internal thread 1 "
Internal thread 1 "
Ope rating
te mperature
(°C)
>0 – 90
>0 – 90
>0 – 90
>0 – 90