11. Troubleshooting guide

Faults
The equipment
does not start
The equipment
does not pump
Insuffi cient pumping
rate
The equipment swit-
ches off after briefl y
running
Anl_GE_PP_18_RB_Li_SPK9.indb 24
Anl_GE_PP_18_RB_Li_SPK9.indb 24
GB
Cause
Battery is not correctly inserted
- Intake sieve clogged
- Discharge hose kinked
- Intake sieve clogged
- Performance reduced due to heavi-
ly contaminated and abrasive water
impurities
- Battery performance decreasing
- Motor circuit-breaker switches the
equipment off due to excessive wa-
ter contamination
- Water temperature too high; motor
circuit-breaker switches the equip-
ment off
- 24 -
Remedy
Remove battery and insert again
- Clean intake sieve with water jet
- Unkink the hose
- Clean intake sieve
- Clean equipment and replace wear
parts
- Check the battery performance and
charge the battery if necessary
- Unplug power plug and clean
equipment and shaft
- Ensure that maximum permissible
water temperature (35 °C) is not
exceeded