Mounting And Connection; Mounting The Device; Connecting The Device - HQ-Power VDPL5X5MH Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

strobe rate from 0 - 10 Hz
colour temperature from 2800 to 10000 K
optional control: MediaMaster Express
5.
Overview
Refer to the illustrations on pages 2 and 3 of this manual.
a
handle (x2)
b
rubber foot (x4)
c
fuse holder
d
powerCON
e
powerCON
f
5-pin XLR output
g
3-pin XLR output
n
mounting clamps
o
Omega brackets
6.

Mounting and Connection

Choose a suitable mounting spot. Mount the device in the desired angle using the included bracket.
Connect the power cord to the mains. Disconnect after use.
6.1

Mounting the Device

Refer to the illustrations on page 3 of this manual.
Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable norms.
The carrying construction must be able to support 10 times the weight of the device for 1 hour
without deforming.
The installation must always be secured with a secondary attachment e.g. a safety cable.
Never stand directly below the device when it is being mounted, removed or serviced. Have a
qualified technician check the device once a year and once before you bring it into service.
Install the device in a location with few passers-by that is inaccessible to unauthorised persons.
Overhead mounting requires extensive experience: calculating workload limits, determining the
installation material to be used... Have the material and the device itself checked regularly. Do not
attempt to install the device yourself if you lack these qualifications as improper installation may
result in injuries.
For truss mounting, use an appropriate clamp (not incl.) and fit an M10 bolt through the centre of the
(folded) bracket.
Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws.
Make sure there is no flammable material within a 0.5 m radius of the device.
Have a qualified electrician carry out the electric connection.
Connect the device to the mains with the power plug. All devices must be powered directly off a
grounded switched circuit. Do not connect to a dimmer pack.
The device has a power output to supply power to another device. When connecting several devices
in a daisy chain via this output, make sure that the total current does not exceed the power line's
nominal current. Use power cables with an adequate section.
The installation has to be approved by an expert before the device is taken into service.
6.2

Connecting the Device

Power
Connect the device to the mains with the power plug.
Power all devices directly off a grounded switched circuit.
Do not connect the device to a rheostat or dimmer circuit, even when using the rheostat or dimmer
channel solely for 0 % to 100 % switching.
Have a qualified electrician carry out the electric connection.
V. 03 – 18/11/2014
®
output
®
input
VDPL5X5MH
h
etherCON
i
LED indicators
j
LCD display
k
control panel
l
3-pin XLR input
m
5-pin XLR input
p
safety cable
6
®
through ports
©Velleman nv