L3
DECELERATION
L4
LEAVES DELAY
L5
RELEASE STROKE
L6
SLAM LOCK
L7
COURTESY LIGHT
LEV
MENU
1. PHOTOCELLS TEST:
The control unit is factory set with the photocells test disabled; proceed
as follows if you wish to enable the function: make sure you have enabled
extended Menu 1, use the select key to select blinking LED L1 and then
press the SET key; at the same time LED L1 will become steady on and
programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
2. PED MOT. T. (Programming of pedestrian opening motor time of
max 4 minutes):
The control unit is factory set with Motor time (Pedestrian opening) of 10
seconds without any deceleration.
If the pedestrian motor time must be changed, programming must be carried
out with the gate closed as follows: ensure you have enabled Extended Menu
1, use the SELECT key to select blinking LED L2 and then press the SET
key momentarily. The Operator will start the Opening cycle; when the gate
reaches the desired initial deceleration position press the SET key again: LED
L2 will start blinking more slowly and the Operator performs the deceleration;
when the desired position is reached press the SET key to terminate the
Opening cycle. At this point LED L2 returns to the normal blinking speed
and the Operator restarts in the Closing movement; repeat the operations
described above for the Closing movement.
If you do not require the control unit to perform the deceleration, during
programming, when the opening and closing cycle has been completed
press the SET key twice consecutively rather than just once.
During programming, instead of the SET key on the control unit you can use
the button on the remote, providing the remote has been saved beforehand
3. DECELERATION:
As indicated above, the control unit allows a deceleration stage to be
programmed during opening and closing, while with the Automatic
Programming function the deceleration stage is included automatically.
However, if no deceleration is required, this stage can be inhibited. In this
manner, when using Automatic Programming the Deceleration stage will no
longer be included, while if the Motor Times Programming function is used
the option of specifying a deceleration stage during opening and closing
will no longer be available. If, before excluding the deceleration stage it had
already been programmed using the Motor Times Programming function,
programming must be repeated from the beginning. If the deceleration stage
is to be excluded proceed as follows: make sure you have enabled Extended
Menu 1, use the SELECT key to select blinking LED L3 and then press the
SET key: LED L3 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the
previous configuration.
4. LEAVES DELAY (15 sec. max leaf delay programming):
The control unit is factory set with leaves opening and closing delay disabled
(4 sec.). If the control unit is used in the configuration for an automation
with 2 operators, it may be necessary to set a different leaves delay time;
programming must be performed with the gate closed as follows: make sure
you have enabled Extended Menu 1, press the SELECT key to select blinking
LED L4 then press the SET key momentarily; now wait for a time equivalent
to the desired time interval and then press the SET key again momentarily, at
the same time the fixed 4 second leaves opening delay and the closing delay
for the programmed time will be saved and LED L4 will remain steady on.
If you want to deactivate this function (without leaves delay), select blinking
LED L4 and then press the SET key twice consecutively in a time interval of
2 seconds, at the same time the LED will switch off and the operation will be
terminated.
5. RELEASE STROKE:
The control unit is factory set with the release stroke function disabled. To
enable the Release Stroke function at maximum power, proceed as follows:
make sure you have enabled Extended Menu 1, use the SELECT key to
select blinking LED L5 then press the SET key, LED L5 becomes steady on
and the programming procedure will be completed. If you wish to enable the
Release Stroke function at the power set with the "FORCE" trimmer, repeat
the procedure described above,
22
COMUNELLO ®Copyright 2014 - All right reserved
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
1 FLASH
press the SELECT key twice (LED L5 will blink rapidly) rather than just once.
Repeat the procedure if you wish to restore the initial configuration.
This procedure makes it possible to facilitate release of the gate lock and
thus allow correct execution of the opening stroke. With this function, before
starting the opening stroke the control unit sends a closing command for 2
seconds with the thrust force associated with the selection made.
6. SLAM LOCK:
The control unit is factory set with the Slam Lock function disabled. This
function consists in adding, in the presence of a deceleration stage during
closing, a stroke lasting 1 second at the maximum power or at the power
selected with the "FORCE" trimmer, in such a way as to ensure positive
engagement of the gate lock, if installed. If you wish to enable the Slam
Lock function at maximum power, proceed as follows: make sure you have
enabled Extended Menu 1, use the SELECT key to select blinking LED L6
and then press the SET key: LED L6 becomes steady on and programming
will be completed. If you wish to enable the Slam Lock function at the power
set with the "FORCE" Trimmer, repeat the operation described by pressing
the SELECT key twice (LED L6 will blink rapidly) rather than once. Repeat the
procedure if you wish to restore the initial configuration.
7. PREFLASHING/COURTESY LIGHT:
The control unit is factory set with the Preflashing and Courtesy Light functions
disabled. If you wish to enable the Preflashing function proceed as follows:
make sure you have enabled Extended Menu 1, use the SEL key to select
blinking LED L7 and then press the SET key: the LED becomes steady on
and programming will be completed. If you wish to enable the Courtesy Light
function, repeat the operation described above, pressing the SET key twice
(the LED will blink rapidly) rather than once. Repeat the procedure if you wish
to restore the initial configuration.
Preflashing Operation: The 24 V
always switch on 3 seconds before the gate starts the closing operation.
Courtesy Light Operation: The 24 V
will switch on for 3 minutes whenever an opening command is transmitted.
EXTENDED MENU 2
The control unit is factory set to allow direct selection exclusively of the main
menu functions. If you wish to enable the functions described in Extended
Menu 2, proceed as follows: select blinking LED no. 8 and press SET twice.
The LED will start blinking alternately 1 1 0 1 1 0 1 1 0. This means there is a
period of 30 seconds to select the functions in Extended Menu 2 using the
SELECT and SET keys and then, after a further 30 seconds, the control unit
will revert to the main menu.
L1
SOFT STOP
L2
SOFT START
L3
SAFE 1 IN OPEN
L4
HOLD-TO-RUN
L5
FOLLOW ME
L6
PAUSE FLASHING
L7
ALWAYS CLOSE
LEV
MENU
1. SOFT STOP:
The control unit is factory set with the Soft Stop function disabled. If you
wish to enable the function, proceed as follows: ensure you have enabled
Extended Menu 2 and then use the SEL key to select blinking LED L1
and press the SET key; at the same time LED L1 becomes steady on and
programming will be completed. With this function enabled at the end of the
movement the control unit will reduce operator force to zero gradually in a
2 second interval. Repeat the procedure if you wish to restore the previous
configuration.
2. SOFT START:
The control unit is factory set with the Soft Start function disabled. If you wish to
enable the function, proceed as follows: ensure you have enabled Extended
Menu 2 and then use the SELECT key to select blinking LED L2 and press
the SET key; at the same time LED L2 becomes steady on and programming
will be completed. With this function enabled at the start of each movement
the control unit will modulate start-up of the operator, gradually increasing the
force from the minimum to the value set by the "FORCE" trimmer during the
first 2 seconds of operation. Repeat the procedure if you wish to restore the
previous configuration.
Note: when the Soft Start function is enabled, the control unit automatically
4W max. Flashing Light output will
4W max. Courtesy Light output
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
2 FLASHES