Vent
system
chart
NOTE: Side and bottom
exhaust
installations
have a 90 ° turn inside the dryer. To determine
maximum
exhaust
length,
add one 90 ° turn to the chart.
Number
of 90 °
Type of
Box or Iouvered
Angled
turns or elbows
vent
hoods
hoods
0
Rigid metal
64 ft (20 m)
58 ft (17.7 m)
Flexible metal
36 ft (11 m)
28 ft (8.5 m/
1
Rigid metal
54 ft (16.5 m)
48 ft (14.6 m)
Flexible metal
31 ft (9.4 m)
23 ft (7 m)
2
Rigid metal
44 ft (13.4 m)
38 ft (11.6 m)
Flexible metal
27 ft (8.2 m)
19 ff (5.8 m)
3
Rigid metal
35 ft (10.7 m)
29 ft (8.8 m)
Flexible metal
25 ft (7.6 m)
17 ff (5.2 m)
4
Rigid metal
27 ft (8.2 m)
21 ff (6.4 m)
Flexible metal
23 ft (7 m)
15 ff (4.6 m)
1.
2.
3.
Install exhaust
hood.
Use caulking
compound
to seal exterior
wall opening
around
exhaust
hood.
Connect
vent to exhaust
hood. Vent must fit inside exhaust
hood.
Secure vent to exhaust
hood with
4" (10.2 cm) clamp.
Run vent to dryer location.
Use the straightest
path possible.
See "Determine
vent path" in
"Plan Vent System."
Avoid
90 '_ turns.
Use clamps to seal all joints.
Do not use duct tape,
screws or other fastening
devices that extend
into the interior
of the vent to secure vent.
Excessive
Weight
Hazard
Use two or more people
to move and install
dryer.
Failure
to do so can result
in back or other
injury.
lb protect
the floor,
use a large flat piece of cardboard
from the dryer carton.
Place
cardboard
under the entire
back edge of the dryer.
2.
Firmly grasp the body of the dryer (not the console
panel).
Gently
lay the dryer on the
cardboard.
See illustration.
Examine
the leveling
legs. Find the diamond
marking.
1
4.
Screw the legs into the leg holes by hand. Use a wrench
to finish turning
the legs until the
diamond
marking
is no longer
visible.
5.
Place a carton
corner
post from dryer packaging
under each of the 2 dryer back corners.
Stand the dryer up. Slide the dryer on the corner
posts until it is close to its final location.
Leave enough
room to connect
the exhaust
vent.
1.
Ushlg
a
4" (10.2 cm)
clamp,
connect
vent to exhaust
outlet
in dryer. If connecting
to
existing
vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust
outlet
and inside the exhaust
hood. Check that the vent is secured to exhaust
hood with
a
4" (10.2 cm) clamp.
2.
Move dryer into its final location.
Do not crush or kink vent.
3.
(On gas models)
Check that there are no kinks in the flexible
gas line.
4.
Once the exhaust
vent connection
is made, remove
the corner posts and cardboard.
L<., el l)rve
#I
i
I
/
Check the levelness of the dryer. Check levelness
first side to side, then front to back.
1i;%
%
(i)_%
]]
If the dryer is not level,
prop up the dryer using a wood block.
Use a wrench
to adjust the legs
up or down
and check again for levelness.