3. Part : INSTALLATION AND PREPARATIONS FOR USE
While your appliance operates, its outside surfaces heat up. Even if the
appliance is turned off, these parts keep its heat for a specific time. Do not
touch onto hot surfaces, and keep children away.
Do not leave the appliance while cooking with solid or liquid oils. They may
catch fire on condition of extreme heating. Never pour water to the flames
that are caused by oil. Cover the saucepan or frypan with its cover in order
to choke the flame that has occured in this case and turn the appliance off.
The heat adjustment switches must be adjusted for cooking in your
appliance.
Plug the appliance off the electrical network when you do not use the
appliance and keep the gas valve off.
Protect your appliance against atmospheric effects. Do not leave it to effects
such as sun, rain, snow, powder etc.
Remember that this appliance is designed for indoor use.

3.7. Gas conversions

Caution : The following procedures must be undertaken by authorized
service personnel.
Your appliance is adjusted to be operated with LPG gas. The gas burners can be
adapted to different types of gas, by replacing the corresponding injectors and
adjusting minimum flame length suitable to the gas in use. For this purpose,
following steps should be performed:
Changing injectors:
Cut off the feeding gas flow and electric current
Remove the hob cap and the adapter.
Unscrew the injectors. For this, use a 7mm spanner.
Replace the injector with the ones from the spare set, with corresponding
diameters suitable to the type of gas that is going to be used, according to
the information chart (which is also supplied in the spare set).
Figure 9
.
Figure 10