CONTROL PANEL

AM x-10 F1 Micro
Rotar MICRO SE- fig.4
1. Air pressure gauge:
outlet air pressure reading
2. ON/OFF switch:
starting and stopping the compressor
3. Service hour counter:
operation hours reading
WORKING TIMES
Rotar MICRO TA - fig.5
The Rotar Micro TA version is equipped with an electronic
AM x-10 F1 Micro
Micro SE
control called "Easytronic II Micro" which manages all of the
• START-STOP function: the compressor starts from the
compressor functions
pressure switch command. When maximum pressure is reached
it stops and restarts automatically only if the minimum pressure
1. START key:
value allowed is reached.
controls start up of the compressor.
2. RESET key:

Pressure regulator

controls turning off of the compressor.
3. "Function" key:
The User should install an intercepting and regulating device
allows movement from one display to the other.
downstream of the compressor in order to set the air distribution
4. Display:
line according to his/her needs.
shows the information.
5. Alarm warning lights:
turn on in case of alarm.
6. Screw warning light:
turning on means that the compressor is loading.
7. Stand-by warning light:
turning on indicates the compressor is waiting.
8. Emergency shutdown button:
pressing this button causes immediate stoppage of the
compressor. To be used only and exclusively in the event of
real need.
WORKING TIMES
MICRO SE
START-STOP function: the compressor starts from the
pressure switch command. When maximum pressure is
reached it stops and restarts automatically only if the
minimum pressure value allowed is reached.
MICRO TA
The compressor function is regulated by the electronic
control unit, which measures the pressure by means of a
pressure transducer and determines the stopping of the
machine when the maximum pressure is reached (vacuum
pressure) and it restarts when the pressure decreases to the
minimum calibration level (load pressure)
The machine stop is a delayed type that does not occur
at exactly the same time as reaching maximum P value but
after a certain time (vacuum time), during which no air is taken.
The factory vacuum time is 75 seconds but check that
the n° of switch on per hour DO NOT exceed the max advised
n° of 10. If above 10, increase the "vacuum time", in order to
avoid not necessary switch on and switch off cycles.
PRESSURE REGULATOR
The User should install an intercepting and regulating
device downstream of the compressor in order to set the
air distribution line according to his/her needs.
8 8 8 8 8
Rotar Micro - Cod.197CC2300 - Rev.01 - 07/2008

CONTROLS AND SETTINGS

10
5
0
15
ON
OFF
4
3
5
4
1
2
3
5
8
6
AIR
1
STAND-BY
START
2
STOP
7