The lithium-ion battery can be charged at any charging level and charging can be interrupted at
any time without damaging the battery (no memory effect).
 Insert plug of the battery charger into a wall socket: Red and green LEDs are lit.
 Connect the battery (1) to the battery charger (2): Charging control light (3) flashes green:
Battery is charged. Charging control light (3) is lit green: Battery is fully charged. (For charg-
ing time, see Technical Data).
 Keep button pressed and remove the battery.
 Disconnect plug from the wall socket.
Storage:
The place of storage must be inaccessible to children.
 Keep button pressed and remove the battery.
 Disconnect plug from the wall socket.
 Store battery charger in a dry, frost-proof location.
Store the battery only in a charged state! Fully recharge the battery after 12 months of stor-
age, at the latest!
Troubleshooting:
Before evaluating faults, disconnect the plug!
- Fault lamp (4) is lit red: Battery temperature outside the permissible charging temperature
(5°C to 45°C).
- Fault light (4) flashes red: Battery is defective.
If the battery temperature is between 5°C and 45°C and the red fault light (4) is nevertheless lit,
there may be a faulty contact.
- Clean contact points on battery.
In the event of other faults, please contact ROTHENBERGER Service. Repairs should only be
carried out by ROTHENBERGER service centres or dealers authorised by ROTHENBERGER.
3.4

Changing the battery

 Open the rear cover (5).
 Insert the battery into the compartment on the right side of the accessory compartment until
it clicks. To remove, press the locks and pull the battery out.
3.5

Working with the device

Wear protective clothing! Always stand next to the reel cable!
 Push reel cable (4) with bending spring (3) from the holder (10) / reel (8) take and remove
cap.
 Remove the cap from the camera head (1) and screw on the bending spring (3).
Caution: Check for cleanliness and damage!
 If necessary, additional accessories can be attached to camera. When using pipe diameters
greater than 70 mm, always use guide body!
 Clean the pipe system before inspection.
 Press button on the bottom cover (6), open the cover. Hold the door during opening.
 Turn the device on with the Power-button, located bottom front center of the monitor (7). The
monitor unit (7) can be removed from the basic device for optimal viewing angle.
Excessive pressure on the touch screen may damage the monitor unit!
 Remove the camera head (1) from the holder (10) and pull the cable (4) from the reel (8).
The cable is rigid and is under mechanical stress. Therefore, hold it firmly when unwinding
from the reel. By pressing in the holder / bracket (10), it can be clamped!