Water Circuit - Master BC 340 Manual De Instrucciones

Ocultar thumbs Ver también para BC 340:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
en
►ANION: Enables or disables the
ionisation mode, that is, the release
of negative ions in the atmosphere, to
make air healthier.
NOTE: When the control panel
display shows the icon "TANK"
(flashing), accompanied by a beep,
it means that the tank is empty and
must be refilled to reactivate the
COOL function.
►►4.2.2. REMOTE CONTROL
AND FUNCTIONS (Fig. 8):
►POWER: Turns on or off the device.
►LOW - MID - HIGH: Increases or
decreases the ventilation speed of the
device. You can choose from three
speeds: LOW, MID and HIGH.
►COOL: Enables the cooling mode.
CAUTION: By pressing this button,
ventilation
activates
seconds.
►WIND: Enables the ventilation mode
ONLY.
►ION: Enables or disables the ionisation
mode, that is, the release of negative
ions in the atmosphere, to make air
healthier.
►TIMER: If the device is off, it allows
programming the delayed start. You can
choose between one-hour intervals.
►TIMER: If the device is on, it allows
programming the automatic switch-
off. You can choose between one-hour
intervals.
►►4.3. SWITCHING OFF:
►4.3.1. Press the ON/OFF / POWER
button to switch off the appliance (Fig.
9).
►4.3.2. Empty the tank using the drain
cap (Fig. 10-11-12).
Figures and texts of this book are protected by COPYRIGHT.
after
a
few
►►5. CLEANING AND
MAINTENANCE
WARNING: BEFORE PERFORMING
ANY MAINTENANCE OR REPAIR,
DISCONNECT THE POWER CABLE
FROM THE MAINS.
DEPENDING ON THE ENVIRONMENT
WHERE THE APPLIANCE IS USED,
DUST, DIRT OR WATER QUALITY CAN
AFFECT THE PERFORMANCE OF THE
UNIT. THEREFORE, CLEANING THE
FOLLOWING COMPONENTS CAN BE
NECESSARY:
►►5.1. TANK:
We recommend changing the water
frequently.
►5.1.1. Switch off the appliance and
disconnect the plug from the mains
(Fig. 9-6).
►5.1.2. Remove the drain plug and
empty the vessel, then wash it, using
a soft cloth. Wash away the dirt from
the water sensor, water pump and float
valve. Rinse everything.
►5.1.3. In order to clean the housing, use
delicate soap and a soft cloth. Do not
use any caustic detergents, which may
damage the air conditioner housing.
►5.1.4.
In
order
accumulation of algae and other
biological organisms in the vessel,
add chlorine or bromine tablets or
other tablets recommended by the
manufacturer regularly, intended for the
vessels of evaporation air conditioners.
►►5.2. WATER CIRCUIT:
►5.2.1. To ensure proper operation of
the cooler, turn off COOL mode a few
minutes before completely switching
off the appliance, in order to avoid
stagnant water.
►5.2.2. Once a month we recommend
performing a complete cycle using
clean water and appropriate disinfection
products, running the cooler outdoors.
to
prevent
the
Tabla de contenido
loading

Tabla de contenido