4. Operation
Automatic operation:
Manual operation:
27.07.2011
15:50 Uhr
The float switch
level exceeds the cut-in height and the water is pumped out.
The float switch
level falls below the cut-out height.
1. Stand the pump on a firm surface
– or –
use a rope attached through the bore hole in the carrying
handle
to immerse the pump in a well or shaft.
During automatic operation, ensure that the float switch
move freely.
2. Plug the power cable
Adjusting the Cut-in and Cut-out Height:
(Minimum depth for switching on and off, see 8. Technical Data.)
➔ Push the cable of the float switch
.
Do not select a cable length that is too long or short to ensure
that the float switch can turn on and off properly.
The cable length between the float switch
lock
must always be at least 10 cm.
• The shorter the length of cable between the float switch
the float switch lock
higher the cut-out height.
To ensure that the pump can draw in water, the level must be
above the minimum water level at start-up (see 8. Technical
Data).
The pump remains constantly in operation because it is switched
on manually by raising the float switch.
1. Stand the pump on a firm surface
– or –
use a rope attached through the bore hole in the carrying
handle
to immerse the pump in a well or shaft.
2. Plug the power cable
3. Fix float switch
at the bottom).
As long as the float switch is positioned vertically above the
pump, the pump will operate regardless of the water level.
The minimum residual water depth (see 8. Technical Data) is
only achieved in manual mode because the float switch already
switches off the pump before this when in automatic mode.
Seite 13
turns the pump on automatically when the water
turns the pump off again as soon as the water
into a mains socket.
into the float switch lock
, the lower the cut-in height and the
into a mains socket.
vertically above the pump (with the cable
can
and the float switch
and