DIFFICULTY
Device locked in the raised
position
Comes down freely without
brake
Goes up with difficulty
The device does not lock in
one of its adjustment
positions
NOTE :
- If the problem persists, contact the After-Sales Department
- For any spare parts order, refer to the exploded view, page 1 for the LEVPANO
LEVPANO
II
F – PROCEDURE FOR CHANGING THE TWO CABLES
Material required :
One 8 mm open-ended spanner
Pliers
One end-fitting cable spare kit ref. PR 0012 comprising : 2 universal cables and 1 spring.
1) Removing the safety and traction cables
a) In the working position, remove the head, beam and arm assembly from the head extension tube
after removing the pin situated at the bottom of the head.
b) Unwind the winch's 2 cables completely (pull on them). The 2 cables are fixed on the winch's
reel by means of 2 cable clamps. Remove the 2 cable clamps on the outside of the reel then, using
the 8 and 10 mm open-ended spanners, unscrew the 2 cable clamps. The 2 cables are thus
released.
c) Undo the M8 lock nut and remove the M8 x 65 hex. head screw in order to remove the top collar
from the intermediate column and to release the frame columns.
d) Take out the inner column ref. 1 and intermediate column ref. 2 assembly (with the cables).
Position this assembly horizontally on 2 trestles (see drawing page 21).
e) Separate the inner column ref. 1 from the intermediate column ref.2 (see drawing page 21).
f) Remove the worn traction cable from the cable hooking support. Replace the latter with the new
cable (see sketch, item A)
g) Using pliers, move the spring's loop away so as to disengage the spring from the column.
Replace the worn safety cable with the new cable, fixing one of the loops of the new spring to the
cable's loop. Fix the other loop of the spring to the column (see sketch, item A)
POSSIBLE CAUSE
- Brake locked
- Cables stuck and/or
damaged
- Columns locked
- Excess winch grease
- Tightening of the brake
- Lock washer inoperative
- Presence of foreign matter
- A lock remains blocked
- The beam's pivoting discs
are blocked
One 10 mm open-ended spanner
Circlip pliers
A
20
CORRECTION
Undo the crank handle and put it
back in contact
Check the passage of the cables and
their condition
Check the cleanness of the columns
Degrease the lock washer and the
support
Put the crank handle and the lock
washer in contact
Check the condition of the washer
Clean the device
Clean the locks
Loosen the pivoting discs, grease the
sides in contact and then tighten the
discs back, complying with an
operating play