Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Before
you move your
refrigerator
into its final
location,
it is
important
to make sure you have the proper
electrical
connection.
Recommended
Grounding
Method
A 115 volt, 60 Hz., AC only, 15- or 20-amp
fused, grounded
electrical
supply is required.
It is recommended
that a separate
circuit serving only your refrigerator
be provided. Use an outlet
that cannot be turned off by a switch. Do not use an
extension cord.
NOTE: Before performing
any type of installation,
cleaning, or
removing a light bulb, turn the control (Thermostat, Refrigerator
or Freezer Control depending
on the model) to OFF and then
disconnect the refrigerator
from the electrical
source. When you
are finished, reconnect the refrigerator
to the electrical
source
and reset the control (Thermostat, Refrigerator
or Freezer
Control depending
on the model) to the desired setting. See
"Using the Controls."
Gather the
required
tools and parts before
starting
installation.
Read and follow the instructions provided with any tools listed
here.
TOOLS NEEDED:
Flat-blade
screwdriver
1/4" Nut driver
7/16" and 1/2" Open-end
or two
1/4" Drill
bit
adjustable
wrenches
Cordless
drill
NOTE: Your refrigerator
dealer has a kit available with a 1/4"
(6.35 ram) saddle-type
shutoff valve, a union, and copper
tubing. Before purchasing,
make sure a saddle-type
valve
complies with your local plumbing
codes. Do not use a
piercing-type
or 3/%- (4.76 ram) saddle valve which reduces
water flow and clogs more easily.
IMPORTANT:
All installations
must meet local plumbing code
requirements.
Use copper tubing and check for leaks. Install copper tubing
only in areas where the household temperatures
will remain
above freezing.
Water
Pressure
A cold water supply with water pressure of between 30 and
120 psi (207 and 827 kPa) is required to operate the water
dispenser and ice maker. If you have questions about your water
pressure, call a licensed, qualified
plumber.
Reverse Osmosis Water
Supply
IMPORTANT: The pressure of the water supply coming out of a
reverse osmosis system going to the water inlet valve of the
refrigerator
needs to be between 30 and 120 psi (207 and
827 kPa).
If a reverse osmosis water filtration
system is connected to your
cold water supply, the water pressure to the reverse osmosis
system needs to be a minimum of 40 to 60 psi (276 to 414 kPa).
If the water pressure to the reverse osmosis system is less than
40 to 60 psi (276 to 414 kPa):
Check to see whether the sediment filter in the reverse
osmosis system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill
after heavy usage.
If your
refrigerator
has a water
filter,
it may further
reduce
the water
pressure
when used in conjunction
with
a reverse
osmosis
system.
Remove
the water
filter.
See "Water
Filtration
System."
If you have questions about your water pressure, call a licensed,
qualified
plumber.