Dema Injector Maintenance (Wash & Rinse Model) - Clarke Clean Track 16 Instrucciones De Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

AUTHORIZED PERSONNEL MAINTENANCE
DEMA INJECTOR MAINTENANCE (WASH & RINSE MODEL)
1
Follow steps 1 through 7 of the SOLENOID VALVE REMOVAL (WASH & RINSE MODEL) section.
2
See Figure 11. Disassemble the DEMA Injector (A) from the Nozzle Assembly.
3
Remove the (4) Screws (B) and disassemble components (C, D, E, F, G, H, I & J). Clean all components and reassemble. NOTE: If there are
lime deposits inside the injector soak all parts in a deliming agent to remove the deposits.
4
Reassemble the Nozzle Assembly and follow steps 1 through 7 of the SOLENOID VALVE REMOVAL (WASH & RINSE MODEL) section in
reverse order to reassemble.
Tip Color
Tan
Orange
Turquoise (installed from factory)
Pink
FIGURE 11
Install correct metering nozzle from chart
closest to the chemical ratio to be used.
See chemical manufacturer's label for ratio
to be used.
Injector Metered Nozzles (K)
Ratio
102:1
75:1
60:1
43:1
EN
OZ / GAL (nominal)
1
1.5
2
3
FORM NO. 56041660 - Clean Track
ENGLISH / A-15
16, 18 - A-15
®