If the new dryer is being installed into an existing exhaust system, you must
make sure:
*
The exhaust system meets all local, state, and national codes.
That a flexible plastic duct is not used.
To Inspect and clean all lint buildup from inside the existing duct.
The duct is not kinked or crushed.
The exhaust hood damper
opens and closes freely.
The static pressure
in any exhaust system must not exceed
0.83 inches of water
column or be
less than 0.
This can be measured
while the dryer is running with a manometer
at the point where the
exhaust duct connects
to the dryer. A no-heat
setting
should be used. The dryer tumbler should
be empty and the lint filter clean.
IMPORTANT
INFORMATION
FOR INSTALLER
Please read the following
instructions
carefully before installing the dryer. These instructions
should be kept
for future reference.
,4k
REMOVE THE DOOR FROM ALL DISCARDED
APPLIANCES
TO AVOID THE DANGER
OF A CHILD
.......
SUFFOCATING.
LOCATION
CONSI DERATIONS
Locate the dryer where there is enough space at the front for loading
and enough space behind for the
exhaust system.
This dryer is factory-ready
for rear exhaust.
To exhaust out the bottom
or the left, use
the accessory
exhaust kit. Instructions
are included
with the kit. It's important
to make sure the room has
enough fresh air. The dryer must be located
where there is no air-flow obstruction.
For gas dryers, you must provide the clearance
noted on the data plate to ensure adequate
air for
combustion
and proper dryer operation.
DO NOT INSTALL OR STORE THE DRYER IN AN AREA WHERE
IT WILL BE EXPOSED TO WATER AND/
OR WEATHER.
KEEP THE DRYER AREA CLEAR OF COMBUSTIBLE
MATERIALS,
GASOLINE,
AND
OTHER FLAMMABLE
VAPORS AND LIQUIDS.
A DRYER PRODUCES
COMBUSTIBLE
LINT. THE AREA
AROUND
THE DRYER SHOULD
BE KEPT LINT-FREE.
ALCOVE
OR CLOSET
INSTALLATION
Z_
You must vent the dryer to the outside to reduce the risk of fire when installed in an alcove or closet.
WARNING
No other fuel-burning
appliance
should be installed in the same closet as the dryer.
WARNING:
To reduce the risk of fire, YOU MUST VENT THIS DRYER TO THE OUTDOORS.
See the EXHAUST
INFORMATION
section.
Minimum
clearances
between
the dryer and adjacent
walls or other surfaces
are:
2" in front,
17" on top, 1" on either side, and 5" in the back.
The closet front must have two unobstructed
air openings
for a combined
minimum
total area of 72 in2
with 3" minimum
clearance
on the top and bottom.
A Iouvered door with equivalent
space clearance
is
acceptable.
English o 10